Mooney Series 20 Relief Valve Instruction Manual  |  5

Copyright 2021 Baker Hughes Company. All rights reserved.

Product Introduction

Figure 1 

Mooney Series 20 Relief Valve.

The Mooney Series 20 Relief Valve included in this manual is an 

over-pressure protection device designed to be used with a self-

contained pilot valve system. This device is intended for use on 

DOT regulated applications and shall NOT be used to meet the 

requirements for ASME Section VIII.
The  Mooney  Series  20  Relief  Valve  consists  of  five  main 

components (Figure 1):

A.    Main valve 

 

 Available  in  inlet  sizes  1.5”  through  8”,  with  a  full-bore 

orifice, the main valve contains a seat O-Ring to maintain 

a bubble tight seal and a nozzle O-Ring to isolate the dome 

from the inlet and outlet ports. Assembly and disassembly 

of the main valve are accomplished through top entry. When 

there is no pressure in the system, routine maintenance, 

such as replacement of O-Rings and seals, may be done 

with the main valve in place.

B.  Mooney Series 20 or 20H Pilot in Back Pressure (BPV) 

Mode 

 

 The  Series  20  Pilot  is  an  independent  pneumatically 

operated flowing auxiliary device intended for controlling the 

main valve. While the Series 20 Pilot is able to be configured 

in either pressure reducing or back pressure (BPV) modes, 

it  should  only  be  used  in  the  back  pressure  (BPV)  mode 

when installed on the Consolidated* main valve assembly. 

C.  Mooney Type 25 Restrictor

 

 Designed exclusively for the Mooney Series 20 Relief Valve, 

the Type 25 Restrictor has a variably controlled orifice with 

a range setting of ‘0-5’. Adjustment of the restrictor affects 

the  response  rate,  stability,  and  sensitivity  of  the  valve. 

Smaller restrictor openings result in higher gain (sensitivity) 

and slower closing speeds. Larger openings result in lower 

gain  (greater  proportional  band),  greater  stability  and 

faster  closing  speeds. The Type  25  Restrictor  is  required 

for normal valve operation. The recommended and factory 

setting for optimal performance is ‘2’.

D.      Inline  Filter 

 

 A  15  micron  inline  filter  is  recommended  on  all  Mooney 

Series 20 Relief Valves. This inline filter serves to limit debris 

particles from entering the supply line of the pilot. 

E.    Field Test Connection

 

 A  field  test  connection  is  recommended  for  the  Mooney 

Series 20 Relief Valve. This allows the stroking of the valve 

with an auxiliary media, e.g. air or nitrogen in order to 

establish the desired pressure set point. An internal check 

valve is present in the field test connection isolating the inlet 

media from the test media and at the same time, allowing 

the valve to open normally in the event of a system over 

pressurization during a field test.

Specifications

Specifications

Main Valve Orifice

Full-bore

Sizes

1.5” (40mm) through  

8” (200mm) inlet

Body Style

1.5” through 4” Inlet – Single Outlet
6” through 8” Inlet – Dual Outlet

Inlet Ratings

ASME/ANSI Class 150 through 300

Outlet Ratings

ASME/ANSI Class 150

Temperature Range

-20°F to 150°F (-29°C to 66°C)

Pressure Range

15 psig to 740 psig

End Connections

Raised-face flanges

Materials

Carbon Steel or 316 SST Main Valve
Brass or SST Pilot

Table 1

Summary of Contents for Mooney 20 Series

Page 1: ...Mooney Series 20 Relief Valve Instruction Manual Rev C Baker Hughes Data Classification Public...

Page 2: ...ICULAR RE QUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE...

Page 3: ...rd In some instances of human hazards the pictorial may instead depict what preventive measures to take such as wearing protective equipment The bottom panel may contain an instruction message on how...

Page 4: ...as air to clean clothing or body parts Never use body parts to check for leakage or discharge rates of areas Pressurized fluids gas air injected into or near the body can cause severe personal injury...

Page 5: ...nce and or disassembly assembly instructions may result in a compromised product which in turn could result in an uncontrolled unexpected loss of containment and release of pressure and heated flammab...

Page 6: ...ents Product Introduction 5 Specifications 5 Nameplate Information 6 Principle of Operation 7 Installation 8 Remote Sensing 8 Startup and Operation 9 General Planning for Maintenance 9 Disassembly of...

Page 7: ...oney Series 20 Relief Valve the Type 25 Restrictor has a variably controlled orifice with a range setting of 0 5 Adjustment of the restrictor affects the response rate stability and sensitivity of the...

Page 8: ...Line Size of the Valve Inlet X Outlet RV Figure Number ANSI ASME CL Inlet Class flange rating Max Inlet Maximum Operating Inlet Pressure psig YR Year Manufactured S O Sales Order Number Max Temp Maxim...

Page 9: ...disc begins to lift with the inlet pressure force The force balance at this moment is equal between system pressure in the sense chamber and the main pilot spring As the pressure increases or decrease...

Page 10: ...pressure in the system or equipment to be protected and the pressure at the relief valve inlet exceeds 3 the sensing line to the pilot valve can be connected directly to the process system rather tha...

Page 11: ...is ready to accept flow 5 Slowly open valve upstream to pressurize the relief valve a The relief valve should lock up with zero pressure flow downstream 6 If an auxiliary bottle is used recommended a...

Page 12: ...Disassembly of the Main Valve 1 Loosen and remove the Nuts or Cap Screws on the Cover Plate 2 Lift off the Cover Plate and Bracket 3 Remove the Spring from the top of the Disc 4 Install a lifting bol...

Page 13: ...on b Bottom of the flange and intersecting surface are damaged from galling and or tearing 7 O Ring Seated Disc The O Ring Retainer cannot be machined It can be lapped for minor scratches If lapping d...

Page 14: ...s on bottom When installing the Cover Plate make sure the spring coils remain in the groove and centered 7 Install the Cover Plate on top of Base Torque bolts to the values found in table 4 using the...

Page 15: ...rings General Description Figure 11 1 Spring Housing The Pilot Spring Housing is provided with a 1 4 inch NPT vent connection which may be piped to a safe area or pressure loaded for remote control of...

Page 16: ...nections 1 4 in NPT Temperature Working 20 F to 150 F 6 7 C to 65 7 C Emergency 40 F to 200 F 40 C to 93 3 C Maximum Inlet Pressure 750 psig 103 4 bar Maximum Loading Pressure 750 psig 103 4 bar Maxim...

Page 17: ...e pressure psig to the Inlet and Outlet ports Loading Pressure Maximum allowable pressure psig to the Loading port Spring Case Vent Pressure Maximum allowable pressure psig to the Spring Case Vent por...

Page 18: ...emove Spring Housing Cap Screws and remove Diaphragm Assembly 7 Disassemble Diaphragm Assembly and inspect Diaphragm Replace if necessary Pilot Assembly 1 Diaphragm Assembly Install the Pilot Diaphrag...

Page 19: ...g and Stem Assembly Figure 25 8 Refer to Figure 22 23 Stack the following parts on the Bottom Cap in the order shown in the drawing Return Spring Stem Guide Orifice Spring Orifice Orifice O Ring Back...

Page 20: ...re common Figure 28 3 Plug the outlet NPT port D 4 Increase pressure slowly so the pressure has a chance to stay equalized in both the inlet and dome chambers Smallest restriction is about 3 16 DIA 5...

Page 21: ...s using the following conversion factors Metric values using the following conversion factors Conversion Factor Metric Unit in 25 4 mm lb 0 4535924 kg in2 6 4516 cm2 ft3 min 0 02831685 m3 min gal min...

Page 22: ...20 Baker Hughes Copyright 2021 Baker Hughes Company All rights reserved Notes...

Page 23: ...Mooney Series 20 Relief Valve Instruction Manual 21 Copyright 2021 Baker Hughes Company All rights reserved Notes...

Page 24: ...ost current information The Baker Hughes logo and Mooney are trademarks of Baker Hughes Company Other company names and product names used in this document are the registered trademarks or trademarks...

Reviews: