background image

Mooney Series 20 Relief Valve Instruction Manual  |  17

Copyright 2021 Baker Hughes Company. All rights reserved.

Lubricate with 

Petroleum Oil 

Grease such as 

LUBRIPLATE 

No. 105®

Figure 21 

Installing the Spring with lubricated Spring Follower

6.    PILOTS WITH PLATED, BLUE, AND PURPLE SPRINGS: 

Install Closing Cap with Adjusting Screw and Sealing Nut 

and O-Ring.

Figure 22 

Installing the closing cap assembly for Pilot with the Red, 

Plated, Blue, and Purple Springs

7.    PILOTS  WITH  BLACK  AND  GREEN  SPRING:  Install 

Closing Cap with Adjusting Screw, Spacer, Sealing Nut, and 

O-Ring. The spacer prevents the Black and Green springs 

from being over compressed.

Figure 23 

Installing the closing cap assembly with spacer (to prevent 

spring over compression) for Pilots with the Black and 

Green Springs.

Figure 24 

The Plug and Stem Assembly

Figure 25

8.    Refer to Figure 22 & 23. Stack the following parts on the 

Bottom  Cap  in  the  order  shown  in  the  drawing:  Return 

Spring, Stem Guide, Orifice Spring, Orifice, Orifice O-Ring, 

Back-Up Washer, Plug and Stem

NOTE: The plug on the stem will be ABOVE the Orifice 

Assembly for Relief (BPV) Mode.

9.   Lubricate  both  Body  Insert  O-Rings  with  Parker  O-Lube® 

(or  equivalent  Petroleum  based  Lubricant)  and  install  on 

Body Insert (Cartridge).

10.   Body Insert Assembly: Lift Bottom Cap complete with valve 

mechanism assembly and insert into Body Insert. The Orifice 

Spring should snap the Orifice into place as the Bottom Cap 

is screwed into place. Check the assembly by pushing the 

Stem against a hard surface to make sure it moves freely 

and returns to the extended position.

11.  Measure the Stem Extension: should be .45” (11.43mm)
12.   Lubricate  Stem  O-Ring  with  Parker  Super-O-Lube®  (or 

equivalent Silicon Lubricant) and slip over Stem.

13.   Insert  Body  Insert  into  Pilot  Body  and  screw  into  place 

snugly.

Summary of Contents for Mooney 20 Series

Page 1: ...Mooney Series 20 Relief Valve Instruction Manual Rev C Baker Hughes Data Classification Public...

Page 2: ...ICULAR RE QUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE...

Page 3: ...rd In some instances of human hazards the pictorial may instead depict what preventive measures to take such as wearing protective equipment The bottom panel may contain an instruction message on how...

Page 4: ...as air to clean clothing or body parts Never use body parts to check for leakage or discharge rates of areas Pressurized fluids gas air injected into or near the body can cause severe personal injury...

Page 5: ...nce and or disassembly assembly instructions may result in a compromised product which in turn could result in an uncontrolled unexpected loss of containment and release of pressure and heated flammab...

Page 6: ...ents Product Introduction 5 Specifications 5 Nameplate Information 6 Principle of Operation 7 Installation 8 Remote Sensing 8 Startup and Operation 9 General Planning for Maintenance 9 Disassembly of...

Page 7: ...oney Series 20 Relief Valve the Type 25 Restrictor has a variably controlled orifice with a range setting of 0 5 Adjustment of the restrictor affects the response rate stability and sensitivity of the...

Page 8: ...Line Size of the Valve Inlet X Outlet RV Figure Number ANSI ASME CL Inlet Class flange rating Max Inlet Maximum Operating Inlet Pressure psig YR Year Manufactured S O Sales Order Number Max Temp Maxim...

Page 9: ...disc begins to lift with the inlet pressure force The force balance at this moment is equal between system pressure in the sense chamber and the main pilot spring As the pressure increases or decrease...

Page 10: ...pressure in the system or equipment to be protected and the pressure at the relief valve inlet exceeds 3 the sensing line to the pilot valve can be connected directly to the process system rather tha...

Page 11: ...is ready to accept flow 5 Slowly open valve upstream to pressurize the relief valve a The relief valve should lock up with zero pressure flow downstream 6 If an auxiliary bottle is used recommended a...

Page 12: ...Disassembly of the Main Valve 1 Loosen and remove the Nuts or Cap Screws on the Cover Plate 2 Lift off the Cover Plate and Bracket 3 Remove the Spring from the top of the Disc 4 Install a lifting bol...

Page 13: ...on b Bottom of the flange and intersecting surface are damaged from galling and or tearing 7 O Ring Seated Disc The O Ring Retainer cannot be machined It can be lapped for minor scratches If lapping d...

Page 14: ...s on bottom When installing the Cover Plate make sure the spring coils remain in the groove and centered 7 Install the Cover Plate on top of Base Torque bolts to the values found in table 4 using the...

Page 15: ...rings General Description Figure 11 1 Spring Housing The Pilot Spring Housing is provided with a 1 4 inch NPT vent connection which may be piped to a safe area or pressure loaded for remote control of...

Page 16: ...nections 1 4 in NPT Temperature Working 20 F to 150 F 6 7 C to 65 7 C Emergency 40 F to 200 F 40 C to 93 3 C Maximum Inlet Pressure 750 psig 103 4 bar Maximum Loading Pressure 750 psig 103 4 bar Maxim...

Page 17: ...e pressure psig to the Inlet and Outlet ports Loading Pressure Maximum allowable pressure psig to the Loading port Spring Case Vent Pressure Maximum allowable pressure psig to the Spring Case Vent por...

Page 18: ...emove Spring Housing Cap Screws and remove Diaphragm Assembly 7 Disassemble Diaphragm Assembly and inspect Diaphragm Replace if necessary Pilot Assembly 1 Diaphragm Assembly Install the Pilot Diaphrag...

Page 19: ...g and Stem Assembly Figure 25 8 Refer to Figure 22 23 Stack the following parts on the Bottom Cap in the order shown in the drawing Return Spring Stem Guide Orifice Spring Orifice Orifice O Ring Back...

Page 20: ...re common Figure 28 3 Plug the outlet NPT port D 4 Increase pressure slowly so the pressure has a chance to stay equalized in both the inlet and dome chambers Smallest restriction is about 3 16 DIA 5...

Page 21: ...s using the following conversion factors Metric values using the following conversion factors Conversion Factor Metric Unit in 25 4 mm lb 0 4535924 kg in2 6 4516 cm2 ft3 min 0 02831685 m3 min gal min...

Page 22: ...20 Baker Hughes Copyright 2021 Baker Hughes Company All rights reserved Notes...

Page 23: ...Mooney Series 20 Relief Valve Instruction Manual 21 Copyright 2021 Baker Hughes Company All rights reserved Notes...

Page 24: ...ost current information The Baker Hughes logo and Mooney are trademarks of Baker Hughes Company Other company names and product names used in this document are the registered trademarks or trademarks...

Reviews: