14 | Baker Hughes
Copyright 2021 Baker Hughes Company. All rights reserved.
Materials of Construction
Series 20H & 20HS
Body & Spring
Body & Spring
Housing
Housing
Forged Brass or 303 Stainless
Forged Brass or 303 Stainless
Steel
Steel
Body Insert & Closing
Cap
Brass or 300 Stainless Steel
Diaphragm Spacer
Assembly (20H, 20HS)
300 Stainless Steel
Orifice
300 Stainless Steel or Delrin
(1)
Plug & Stem
Nitrile/300 Stainless Steel
Viton/300 Stainless Steel
300 Stainless Steel
Diaphragm
Nitrile/Nylon or Viton/Nylon
O-Rings
Nitrile or Viton
(1)
Delrin Orifice with all Stainless Steel Plug/Stem is recom-
mended for all set pressures 100 psi and above (Figure 26).
Table 6
Specifications
All Series 20 Pilots
Control Application
Back Pressure (BPV)
Orifice Size
0.15 in (3.81 mm)
Connections
1/4 in NPT
Temperature
Working -20°F to 150°F
(-6.7 °C to 65.7°C)
Emergency -40°F to 200°F
(-40° C to 93. 3° C)
Maximum Inlet Pressure
750 psig (103.4 bar)
Maximum Loading
Pressure
750 psig (103.4 bar)
Maximum Outlet Pressure
750 psig (103.4 bar)
Maximum Emergency
Sensing Pressure
1000 psig (68.9 bar)
Maximum Spring
Housing Pressure
1000 psig (68.9 bar)
Set Pressure Range
15-750 psig (0.2 - 62.1bar)
(2)
(2)
Refer to Table 8 for specific spring ranges.
Table 7
Specifications
Series
Spring Range
Color
Part
Number
20 &
20S
10 - 40 psi (0.7 - 2.7 bar) Plated
040-011-01
25 - 90 psi (1.7 - 6.2 bar) Blue
040-012-01
60 - 200 psi (4 - 14 bar)
Purple
040-008-01
100 - 260 psi (7 - 18 bar)
Black
040-009-01
200 - 450 psi (14 - 31 bar)
Green
040-020-01
20H &
20HS
200 - 520 psi (14 - 36 bar)
Black
(3)
040-009-01
400 - 900 psi (27 - 62 bar)
Green
(3)
040-020-01
(3)
Spacer on Adjustment Screw Required
Table 8
Figure 11
Mooney Series 20 Pilots
Series 20 & 20S
Cartridge
Bottom View all
Constructions
Series 20H & 20HS
6
2
4
3
2
5
3
1A
1