Figure 33: Various Structures in a Well Control System
3.4.6
Templates
A template is a set of channel, trigger, and output configurations that define the functionality for
an application. For example, the Standard template includes predefined channels and triggers
needed in a basic ESP pumping system.
The purpose of a template is to define the functionality of the system. Templates allow the
Apollo system to be pre-configured for a variety of applications, thus minimizing the manual
setup required by the installer.
The following templates are available:
Table 16: Templates
Template
Use
SWB
Use in switchboard and soft-start applications.
Standard
Installed by default. Used in all Vector VII
and Vector Plus applications.
Analog
Use in variable speed drives that Apollo
does not support via a serial (RS-232,
RS-485) connection.
A1KBasicIHM
Mimics the Vector VII (white screen) user
interface. Note that it also Limits
Apollo’s
functionality to that of the Vector VII. Not
recommended for new installations and only
when requested by the customer.
Summary of Contents for Apollo 3