Copyright 2020 Baker Hughes Company. All rights reserved.
Page 16 of 277
Table 1: Quick Start Parameters for Vector Plus and Vector VII Applications (cont'd.)
Parameter Name
Default
Information
DHXFormer Ratio
0.00
Transformer Ratio of the step
up transformer used to drive the
medium voltage motor from the
low voltage drive. Calculated
by dividing the transformer
tap voltage by the transformer
rated input voltage (usually
480 Vac). For example, if a
480 Vac transformer is tapped for
2400 Vac, set the DHXFormer
Ratio to 2400 Vac/480 Vac = 5.0.
Note that the default setting of
0.00 requires this parameter be
set prior to running the drive.
Min Frequency
30.0 Hz
Minimum speed, in Hertz, of
the Vector Plus drive in the
current pumping application.
Min Frequency should be set to
ensure adequate fluid is pumped
past the pump for cooling. For
ESP applications, Min Frequency
settings lower than 30 Hz are not
recommended.
Max Frequency
60.0 Hz
Maximum speed, in Hertz, of
the Vector Plus drive in the
current pumping application.
Max Frequency should be set
to prevent overstressing the
pumping system components.
Accel Seconds
5.0 Seconds
Acceleration ramp time, in
seconds, for the Vector Plus drive
from 0 Hz (stopped) to Maximum
Frequency. For ESP applications,
maximum recommended Accel
Seconds is 10.0.
Summary of Contents for Apollo 3
Page 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Page 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Page 267: ......
Page 276: ......
Page 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...