76
THE ALDE HEA
TING S
Y
STEM
S
hutting
d
own
the
S
yStem
To save energy, the control panel only updates
the boiler after the last adjustment is made.
Wait 10 secs before shutting down the system
to ensure the boiler is updated.
Press the Power button again. The screen goes
dark, the green LED is unlit. The system is off.
S
etup
Most UK installations do not need setting up
in the Settings Menu, and use default factory
settings.
r
eStore
d
efault
f
actory
S
ettingS
Before using the system for the first time,
restore default factory settings. Your control
panel may have been tested by the dealer or
installer, and some settings may have been
changed.
Press Tool button to access the Settings Menu
(bottom right in Main Menu).
Press down arrow, until Reset button is
displayed.
Press the Reset button to proceed.
S
etup
e
xpanSion
t
ank
p
ump
To use the 12v circulation pump in the
expansion tank, you must set it up. This is not a
default factory setting.
NB: Under factory settings, the system will use
the 12v inline circulation pump by default.
Press Tool button to access the Settings Menu
(bottom right in Main Menu).
Press down arrow, until Circulation Pump
button is displayed.
Press Circulation Pump button, select
Expansion Tank Pump to proceed.
S
et
up
a
ntimicroBial
f
unction
To actively kill Legionella, set up the
Antimicrobial function. At 2:00 every night,
the hot water will be heated to over 65°C
for 30 mins. This further reduces the risk of
Legionella.
Press Tool button to access the Settings Menu
(bottom right in Main Menu).
Press down arrow, until Antimicrobial button is
displayed.
Press Antimicrobial button to proceed.
S
etup
S
tandBy
S
creen
for
B
edtime
The backlight on the Standby Screen can be
disturbing if the control panel is visible from
your bed. It can be inverted for white text on
black background.
Press Tool button to access the Settings Menu
(bottom right in Main Menu).
Press down arrow, until Backlight button is
displayed.
Press Backlight button, select Inverted to
proceed.
m
aintenance
The Alde control panel requires no
maintenance, other than cleaning of the screen
as needed. Use a microfibre cloth to clean the
touchscreen.
NB: Consider removing the Alde control panel
over winter, if the vehicle is to be kept in
storage and is susceptible to damp.
t
rouBleShooting
Any error messages will be displayed on
the Standby Screen. Error messages can be
cleared by switching off 12v supply to the boiler
for 10 secs.
The system is completely dead/the control
panel is blank:
Check the 20mm T3.15Amp glass fuse in the
boiler. This is located under the lid of the black
plastic service hatch, in a green plastic fuse
holder.
Check the 12v supply to the boiler, it should be
above 12v.
Check the 12v cable is plugged into the boiler.
Check the cable is plugged into the Alde
control panel.
Panel failure 1 & and Panel failure 2:
Moisture is trapped in the control panel.
Remove the Alde control panel from the
vehicle and air in a warm, dry place overnight.
Gas failure
Out of gas or gas is not igniting.
Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
Overheat red fail or Overheat blue fail:
Bleed the system of air.
Check the fluid level in the expansion tank. It
should be 1cm above min mark when cool.
Check the circulation pump is responding.
Wait 15 mins for the fluid to cool down.
Summary of Contents for ADVANCE 2019
Page 1: ...MOTORHOME OWNER S MANUAL ...
Page 12: ......
Page 27: ......
Page 46: ......
Page 59: ......
Page 141: ...137 THE THETFORD C262 TOILET ...