46
THE G
A
S S
Y
STEM
o
perating
i
nStructionS
- (t
ruma
m
onocontrol
)
1. Open the gas valve on the cylinder.
2. Firmly press the hose rupture protection
(green button) on the high-pressure hose.
3. If necessary (e.g. after a new installation
or after inadvertently striking the
gas cylinder against the gas pressure
regulation system), hold the green
reset button in for at least 5 seconds
before slowly releasing the crash
sensor triggering element reset on the
MonoControl CS.
As standard the Advance/Alliance
range does not have the Truma
Monocontrol regulator fitted.
Therefore on the Advance/Alliance
you will only need to screw open the
gas valve.
Residual gas may be present when
carrying out any task on gas cylinders.
Do not smoke and avoid open flames
or any source of ignition.
g
aS
S
yStem
m
aintenance
The complete gas installation on a motorhome
should be inspected at least once per annum
and as necessary according to usage.
Hoses should conform to BS 3212. It is
advisable to replace hoses annually and in any
case no later than the expiration date marked
on the hose.
Check the following:
• Flexible gas hoses for deterioration. Renew
if necessary or renew no later than the
expiration date marked on the hose.
• The tightness of seals around joints and
connections.
• Make sure that each gas appliance is
working efficiently to the recommendations
of the appliance manufacturer.
• Always ensure that the gas system is
inspected at least every 12 months by a
qualified person.
Always use approved products when replacing
parts.
Please ensure that the hose and
O-ring are correctly installed and not
damaged. Ensure mating surfaces are
clean.
c
hanging
t
he
lpg c
ylinder
Always change gas containers in the open air
to ensure appropriate ventilation.
Please use the spanner provided to attach and
remove the high pressure hose. Ensure you
only use the correct type of cylinder.
1. Extinguish any flame or source of ignition.
2. Close the empty gas cylinder’s gas valve.
3. Remove the high-pressure hose from the
gas cylinder.
4. Attach the high-pressure hose to the full
gas cylinder.
5. Open the cylinder’s valve.
6. Press the hose rupture protection.
h
oSe
r
eplacement
1. Close gas cylinder’s valve.
2. Remove the high-pressure hose from the
gas cylinder and from the regulator inlet.
3. Screw a country-specific high pressure
hose to the MonoControl CS inlet and to
the cylinder.
4. Open the gas cylinder.
5. Press the hose rupture protection and, if
necessary, the reset button.
Summary of Contents for ADVANCE 2019
Page 1: ...MOTORHOME OWNER S MANUAL ...
Page 12: ......
Page 27: ......
Page 46: ......
Page 59: ......
Page 141: ...137 THE THETFORD C262 TOILET ...