5. Check that the power cord has not been damaged during installation.
6.
Connect the ground wire (typically green) to the “
E
” (Safety Ground) terminal (not visible in
this view).
7. Install the electrical box cover.
8. With power connected and the main disconnect turned ON, the control panel will be lit.
9. Push the table up button to raise the table and the table down button to lower the table.
10. If not, disconnect power to the machine, and switch the L1 and L3 wires. DO NOT move the
ground wire.