background image

 

Atom OD15 Mounting 

Bracket 

1 each 

 

 
You  will  need  standard  tools,  Ethernet  cable,  ground  wire,  and  RJ-45  connectors  for  installing  and 
connecting the outdoor unit (Table 2). 

Table 2: Materials 

Item 

Description 

Ethernet Cable 

Outdoor shield CAT5E, shorter than 330 feet 

Ground Wire 

16mm

2

 yellow-green wire 

 

2.2.   LEDs & Interfaces 

On the low-gain UE the LEDs are on the side of the unit, and the connection interfaces are on the bottom of 
the unit. On the high-gain UE both the LEDs and the interfaces are on the side of the unit. Refer to 

错误

!

找到引用源。

  for a description of the LEDs and 

错误

!

未找到引用源。

  for a description of the interfaces. 

Table 3: LEDs 

LEDs vary by model – not all models will have all of the LEDs listed below. 

 

Identity 

Description 

Color 

Status 

Description 

L&S 

LTE network and USIM 

status 

Blue 

Off 

The UE is not connected to the network   

Steady On 

The UE is connected to the LTE network 

PWR 

Power status 

Yellow 

Off 

No power supply to the UE 

Steady On 

Power to the UE is on 

LTE Signal 

L/M/H 3 bars to indicate 

wireless connection 

status. The more bars, 

the stronger the signal 

between the UE and a 

network cell (eNB). 

Green 

All Off 

The signal is too weak for the UE to connect to 

the network 

Steady On 

Bars will light steadily according to signal 

strength   

Blinking 

The UE is scanning the network 

The UE is authenticating with the network 

The UE is getting an IP address from the 

network 

 

Table 4: Interfaces 

Interfaces vary by model – not all models will have all of the interfaces listed below. 

Interfaces 

Description 

PoE 

Power over Ethernet (PoE) power adaptor 

Summary of Contents for ATOM OD15

Page 1: ...1 ATOM OD15 CPE Installation Configuration Guide Model EG8015G M11 April 2020 Version 1 2...

Page 2: ...ark of Baicells Technologies Inc Other trademarks mentioned in this document belong to their owners Revision Record Date Version Description SMEs Contributors Author Editor 18 Nov 2020 v1 0 Tang Houch...

Page 3: ...Mixed Mode 15 2 6 3 WLAN Settings 2 6 4 Static Routes 16 2 6 5 DMZ 17 2 6 6 UPnP 17 2 7 LTE Menu 18 2 7 1 Connection Settings 18 2 7 1 1 Roaming setting 18 2 7 1 2 Default connection 18 2 7 1 3 Power...

Page 4: ...31 2 10 6 1 Firmware Update 31 2 10 6 2 Restore Factory Settings 32 2 10 7 Diagnosis 32 2 10 7 1 TCPDump 32 2 10 7 2 Ping 32 2 10 7 3 Trace 33 2 10 7 4 Result 33 2 10 8 Backup Settings 34 2 10 9 Syste...

Page 5: ...standards based product the Baicells equipment provides higher near line of sight nLOS and non line of sight NLOS signal penetration than other wireless technologies The high gain UE has a higher ante...

Page 6: ...ll work as trunk mode so it can t assign IP address to any no trunk devices like PC so you have to Manual Configure the PC s IP address in the same broadcast domain e g 192 168 150 88 2 IDU ODU Mode W...

Page 7: ...LTE TDD bands 42 43 48 Customization may be requested Complies with 3GPP Release 11 CAT12 15 1000 Mbps Ethernet interface Built in bipolar directional LTE antenna Power supply using Power Over Etherne...

Page 8: ...he LEDs listed below Identity Description Color Status Description L S LTE network and USIM status Blue Off The UE is not connected to the network Steady On The UE is connected to the LTE network PWR...

Page 9: ...ce With the CPE turned on and connected to the router access the GUI login page by opening a Web browser and entering http 192 168 150 1 Figure 2 Login Initially use the default Username admin Passwor...

Page 10: ...er Throughput Statistics you will see downlink DL and uplink UL data rates for current throughput kbps average rates peak rates and total throughput The data is measured during a 3 second interval eve...

Page 11: ...after every LTE connections Software Version ODU CPE operating software version Software Build Time Date and time the software was built SN Serial Number IMEI International Mobile Equipment Identity...

Page 12: ...wnlink data throughput rate in Kbps UL The current uplink data throughput rate in Kbps Average The average DL and UL data throughput rates in Kbps for this CPE in the last 3 minutes Peak The peak DL a...

Page 13: ...LAN Settings Enter the Network LAN DHCP Server enable IP address subnet mask DHCP range lease time UPNP enable Figure 8 DHCP Settings DHCP Static Leases settings can set by the host s MAC address Fig...

Page 14: ...can be configured by Default router Data Mgmt Voip bear types Figure 10 WAN Settings 2 6 2 2 Router Mode When selected Router mode the CPE will worked at router mode it can dynamic update router tabl...

Page 15: ...e CPE worked at Bridge mode the WAN ports address will bridge to LAN port and the LAN port will worked at trunk mode Figure 13 Bridge Mode 2 6 2 5 Mixed Mode Mixed mode can configured every APN with d...

Page 16: ...ode 2 6 3 Static Routes Set Static routes of the CPE it can configure LAN or WAN port routes Gateway Destination Network and Route Subnet Mask in Current Settings show all activated static routes Figu...

Page 17: ...ively you can enable Internet Control Message Protocol ICMP redirect error messages to support Layer 2 multicast features Figure 17 DMZ Settings 2 6 5 UPnP The Universal Plug Play UPnP function provid...

Page 18: ...to other PLMN network else the CPE just can access the network PLMN same with the SIM card 2 7 1 2 Default connection If set always on the CPE will automatic access the LTE network after booting if s...

Page 19: ...nnect to the Baicells CloudCore In the window Figure 42 you will select the APN number 1 8 enable it enter an APN Name select the type of IP addressing IPv4 IPv6 or IPv4v6 identify if it is the defaul...

Page 20: ...n the band The CPE will routinely scan all channels in the band and all EARFCNs increasing the time it takes to connect compared to the other modes The band is dependent on the CPE model Dedicated EAR...

Page 21: ...21 Figure 25 Dedicated EARFCN Figure 26 Cell Lock...

Page 22: ...r s network Figure 48 Each operator has a unique Public Land Mobile Network PLMN number Locking the SIM prohibits the users from accessing another operator s network Figure 28 Throughput Statistics 2...

Page 23: ...Settings 1 IP Port Filtering Mode Blacklist White list 2 IP Port Filtering Log Dropped enable disable 3 Destination IP Address the destination IP Address of the filter 4 Source IP Address the source...

Page 24: ...nge of port 7 Source Port Range the range of port 8 Schedule Index Select box if can be schedule by APPs 9 Remarks 2 8 3 MAC Filtering Media Access Control MAC Filtering allows you to identify a list...

Page 25: ...dden from accessing When you enable the filter a Settings window appears Enter the specific URL address users cannot access as shown in Figure 54 To add more URL addresses click on ADD After entering...

Page 26: ...le disable 5 Block Syn Flood enable disable 6 SPI Firewall enable disable 2 8 6 Connect Limit Connect Limit feature is used to control the number of connections through the UE to a host device for exa...

Page 27: ...set for a group schedule list like start from 2020 8 18 to 2020 8 20 as a index of the schedule Figure 37 Schedule List In previous Filter configurations you can select the schedule index like below f...

Page 28: ...ort Forwarding Field Name Description WAN Port Range Enter the port number range for the remote device in the format of 1000 to 1500 LAN IP Address Enter the local host IP address The address must be...

Page 29: ...ranslation for certain application layer control data protocols such as SIP TFTP PPTP L2TP and IPSeC You can enable the different types of application protocols by clicking on the check box next to th...

Page 30: ...ork devices In the CPE GUI you can refresh the local time display using the SYNC WITH BROWSER button select the time zone that the CPE is in and enable NTP client to use the default or specified NTP s...

Page 31: ...te Caution Do not power off the CPE or disconnect it from the computer during an upgrade To update upgrade the CPE to a different firmware version Figure 67 1 Download the image file from the Baicells...

Page 32: ...utton The CPE will automatically reset its configuration to the factory default values Figure 47 Restore update 2 10 7 Diagnosis 2 10 7 1 TCPDump Figure 48 TCPDump Settings Settings 1 PC IP Address 2...

Page 33: ...URL 3 Count number of ping count 4 Fragment yes or no 5 Packet size 56 1400 Bytes non fragment 2 10 7 3 Trace Figure 50 Trace Diagnosis Settings Settings 1 IPv4 IPv6 Select the protocol 2 IP Address...

Page 34: ...Figure 52 Backup Settings 2 10 9 System Log System log is the debug information of the CPE when select the Setting it can Export or Clear Logs Figure 53 System Log Figure 54 System logs 2 10 10 System...

Page 35: ...35 Figure 55 System Message Settings Figure 56 System Messages 2 10 11 SAS Settings Figure 57 System Message Settings...

Page 36: ...boot of the CPE as shown in Figure 77 It can take several minutes for the reboot to complete After it reboots the CPE GUI will display the login screen Caution The reboot action will disrupt service F...

Page 37: ...dio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not o...

Reviews: