The  list  above  is  for  reference  only.  In  actual  checking  and  repairing, based on 

the national and local codes, ask professional service personnel to operate.

Technical parameter

       

I

   

m

   

p

   

o

   

r

 

t

   

a

   

n

 

t

 

:

      The  parameter  listed  in  the  table  will  be  varied  from  different  place  and 

temperature,please  consultate  to  the  qualificatory  designer  and  architect  for  the  more 

detailed use.

Steam Volume

ml/min

Steam Production Time

(S)  

GEN3-1

TYPE 

GEN3-1

Power Output

Potency Error

Duration

Resistance

Steam Pressure

Applicable space of the 

room (m3)

Water Tank Volume

3

KW

±10%

>1500V

>20MΩ

0.12Pa

140

100-150

2.5L

3~6

4.5

KW

±10%

>1500V

>20MΩ

0.12Pa

160

90-120

2.5L

4~7

6

KW

±10%

>1500V

>20MΩ

0.14Pa

180

100-160

5.7L

5~8

7.5

KW

±10%

>1500V

>20MΩ

0.14Pa

220

90-140

5.7L

7~9

9

KW

±10%

>1500V

>20MΩ

0.14Pa

260

80-130

5.7L

10~12

10.5

KW

±10%

>1500V

>20MΩ

0.16Pa

300

180-240

12L

12~14

12

KW

±10%

>1500V

>20MΩ

0.16Pa

360

150-160

12L

14~16

1

5

KW

±10%

>1500V

>20MΩ

0.16Pa

450

1

2

0-1

5

0

12L

1

8

~

20

1

8

KW

±10%

>1500V

>20MΩ

0.16Pa

500

9

0-1

5

0

12L

20

~

24

Summary of Contents for BAGNOSPA BDD-SPA-GEN3-1-A

Page 1: ...BDD SPA GEN3 1 A BAGNOSPA STEAM GENERATOR 3KW 220V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com...

Page 2: ...tion of the tube 3 Drawing of the steam generator 5 Electric requirements 6 Power line assemble illustration 8 Wiring Diagram 380 415V 3PH 9 Wiring Diagram 208V 3PH 10 Wiring Diagram 220 240V 1PH 2PH...

Page 3: ...link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of...

Page 4: ...let are still very heated after the steam generator have stopped working for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep...

Page 5: ...istant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape...

Page 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using w...

Page 7: ...GEN3 1 Blueprint for the steam engine...

Page 8: ...n independent circuit breaker between the power supply and the steam engine so as to provide an electricity supply with overflow protection and electricity leakage protection All the connection must b...

Page 9: ...ot connect strong electric current to the component directly GEN3 1 Assembly graph for power wire This graph is for explanation only For actual installation refer to national and local electricity con...

Page 10: ...GEN3 1 Wiring Diagram 380 415V 3PH 208V 3PH 220 240V 1PH 2PH...

Page 11: ...light should be installed on the top of the steam room or the places where are not access to the children C C A A U U T T I I O O N N C A UTIO N The illustration is just for explaination the practica...

Page 12: ...ghts exceeding 8 FT ADD 75 D Ceramic tile ADD 75 E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the t...

Page 13: ...it board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105OC Hi limit Transformer 11 12 Terminal block Fuse...

Page 14: ...ether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water...

Page 15: ...e ml min Steam Production Time S GEN3 1 TYPE GEN3 1 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank Volume 3KW 10 1500V 20M 0 12Pa 140 100 150...

Page 16: ...IND SPA GEN3 1 A 12 21 www sanipexgroup com...

Reviews: