background image

Choose your type of machine

!

   

Important: 

  The  calculation  formula  for  selecting  the  type  of  steam  engine  is  for 

reference  only.  Due  to  the  variability  of  the  building,  the  specifications  and  size 
illustration  are  used  as  guidelines  only.  If  we  have  complete  information,  including actual 
blueprint,  project  instruction  and  building  details,  we  can  select  the  type  of  machine 
once  again.  Otherwise,  the  manufacturer  will  not  be  responsible  for  the selection of 
the type of machine.

Measure the length, width and height (foot) of the current steam shower or bathtub room. 
Example;
L:7xW:5xH:8 = 280 Cubic Feet
You would need Model s-900 (it is that simple)
However, if you shower materials are;

A:Natural Stone(Granite or Marble etc.) 

ADD 

75%

B:Exterior walls 

ADD 

75%

C:Celia Heights exceeding 8  FT. 

ADD 

75%

D:Ceramic tile 

ADD 

75%

E:Glass (2 walls) 

ADD 

75%

!

1. Wait for the completion of automatic water discharge after each time of using the steam 

engine  to  make  sure  the  water  in  the  tank  is  discharged  completely  before  cutting  off 
power supply.

2. There  should  not  be  any  leakage  or  damage  among  the  steam  engine,  steam  nozzle, 

components and pipes. They should be checked and repaired annually.

3. Clean the water supply pipes of the steam engine once a year.

4. Check all the connections, faucets and connection terminal to see whether they become 

loose or are damaged due to overheat.

5. Check  the  furring  accumulated  in  the  water  tank  and  electric  heating  tube.  If  the 

furring is thick, dispose it in time (use diluted lemon acid to soak for 15-30 minutes).

6. Remove the water level sensory needle once a quarter to clean the furring in the needle.

Maintenance of the steam engine

Important:    

Perform water discharge operation after each use.

GEN3-1

Summary of Contents for BAGNOSPA BDD-SPA-GEN3-1-A

Page 1: ...BDD SPA GEN3 1 A BAGNOSPA STEAM GENERATOR 3KW 220V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com...

Page 2: ...tion of the tube 3 Drawing of the steam generator 5 Electric requirements 6 Power line assemble illustration 8 Wiring Diagram 380 415V 3PH 9 Wiring Diagram 208V 3PH 10 Wiring Diagram 220 240V 1PH 2PH...

Page 3: ...link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of...

Page 4: ...let are still very heated after the steam generator have stopped working for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep...

Page 5: ...istant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape...

Page 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using w...

Page 7: ...GEN3 1 Blueprint for the steam engine...

Page 8: ...n independent circuit breaker between the power supply and the steam engine so as to provide an electricity supply with overflow protection and electricity leakage protection All the connection must b...

Page 9: ...ot connect strong electric current to the component directly GEN3 1 Assembly graph for power wire This graph is for explanation only For actual installation refer to national and local electricity con...

Page 10: ...GEN3 1 Wiring Diagram 380 415V 3PH 208V 3PH 220 240V 1PH 2PH...

Page 11: ...light should be installed on the top of the steam room or the places where are not access to the children C C A A U U T T I I O O N N C A UTIO N The illustration is just for explaination the practica...

Page 12: ...ghts exceeding 8 FT ADD 75 D Ceramic tile ADD 75 E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the t...

Page 13: ...it board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105OC Hi limit Transformer 11 12 Terminal block Fuse...

Page 14: ...ether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water...

Page 15: ...e ml min Steam Production Time S GEN3 1 TYPE GEN3 1 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank Volume 3KW 10 1500V 20M 0 12Pa 140 100 150...

Page 16: ...IND SPA GEN3 1 A 12 21 www sanipexgroup com...