background image

GEN3-1

Installation of the top light

Light is available in 12V/220V/230V outputs. Before connect to the light, please consult with 
manufacturer  to  know  what  voltage  the  light  is,  so  as  to  avoid  generator  damage  or cause 
danger.
If  the  light  output  is  12V,  the  power  of  the  light  should  not  be  more  than  35W,othwise, 
transformer  will  be  burned  and  cause  danger.  If  light  input  is  220v~240V,light  power 
should not more than 100W.

The  light  should  be  installed  on  the  top  of  the  steam  room  or  the  places  where  are  not 
access to the children.

   

C

C

   

A

A

   

U

U

   

T

T

  

II

   

O

O

   

N

N

    

C

  

A

   

U

  

T

  

I

  

O

  

N

  

:

   The illustration is just for explaination, the practical installation must comply 

with  the  nation's  electric  criterion,and  processed  by  the  professional 

!

The steam control panel           

(Possible location)

The steam 

generator

Light

!

The steam outlet

The steam place 

under the wash parr

(Possible location)

!

CAUTION:

CAUTION:

CAUTION:

 

Take  some moisture proof measures in  process of installation. 

Can not let the electrical components be exposed to moisture or,  it will cause 

damage or short circuit.

Summary of Contents for BAGNOSPA BDD-SPA-GEN3-1-A

Page 1: ...BDD SPA GEN3 1 A BAGNOSPA STEAM GENERATOR 3KW 220V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com...

Page 2: ...tion of the tube 3 Drawing of the steam generator 5 Electric requirements 6 Power line assemble illustration 8 Wiring Diagram 380 415V 3PH 9 Wiring Diagram 208V 3PH 10 Wiring Diagram 220 240V 1PH 2PH...

Page 3: ...link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of...

Page 4: ...let are still very heated after the steam generator have stopped working for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep...

Page 5: ...istant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape...

Page 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using w...

Page 7: ...GEN3 1 Blueprint for the steam engine...

Page 8: ...n independent circuit breaker between the power supply and the steam engine so as to provide an electricity supply with overflow protection and electricity leakage protection All the connection must b...

Page 9: ...ot connect strong electric current to the component directly GEN3 1 Assembly graph for power wire This graph is for explanation only For actual installation refer to national and local electricity con...

Page 10: ...GEN3 1 Wiring Diagram 380 415V 3PH 208V 3PH 220 240V 1PH 2PH...

Page 11: ...light should be installed on the top of the steam room or the places where are not access to the children C C A A U U T T I I O O N N C A UTIO N The illustration is just for explaination the practica...

Page 12: ...ghts exceeding 8 FT ADD 75 D Ceramic tile ADD 75 E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the t...

Page 13: ...it board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105OC Hi limit Transformer 11 12 Terminal block Fuse...

Page 14: ...ether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water...

Page 15: ...e ml min Steam Production Time S GEN3 1 TYPE GEN3 1 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank Volume 3KW 10 1500V 20M 0 12Pa 140 100 150...

Page 16: ...IND SPA GEN3 1 A 12 21 www sanipexgroup com...

Reviews: