Common troubles trouble shooting methods

To facilitate your use and maintenance of sauna room, the following common troubles trouble 
shooting methods are listed for identification.

Troubles

Causes of troubles

Trouble-shooting methods

The machine does 

not start when 

electrified

1. The fuse is burned.

2. The wire connection terminal 

become loose.

3. Not good contact in the connection 

wire between the controller and the 

steam engine.

1. Change the fuse (on the shell 0.8A/ 250V)

2. Plug tight the wire connection terminal

3. Make sure the steam engine and the 

controller come into good contact

Electricity leakage 

switch

breaks 

automatically

1. The wire connector is dampened 

or damaged.

2. The heating tube breaks

1. Check whether the wire connector is 

dampened or damaged, and dry with 

dryer  if dampened.

2. Change a heating tube.

When the machine is 

started, hot water 

comes out with little 

or no steam

1. The water drainage valve is broken.

1. hange a water drainage valve.

The display screen 

on the control panel 

does not display

1. The power wire is not connected 

well or not in good contact. The 

connection plug between the 

control panel and the electrically-

controlled box becomes loose.

2. Trouble  with  plugboard.

1.

Check whether the connection plug 

between the control panel and the 

electrically-controlled box has become 

loose, and whether the power circuitry 

has good contact.

2. change a plugboard.

Water  leakage

1. The water pipe connector becomes 

loose or the pipe breaks

2. Water leakage in the water input 

valve or the water drainage valve

1. Tighten the loose connector, and change 

the broken pipe.

2. Change the water input valve or the 

water drainage valve.

No steam when 

starting the 

machine

1.

No electricity.

2.

No water.

3.

The set temperature is too low

4.

Trouble with wire.

1. Check the power supply

2. Check the water input pipe and water 

input valve

3. Reset the temperature

4. Contact the distributor

The steam does not 

come out, the water 

sounds in the 

machine

1. The steam pipe is jammed.

1. Cut power supply to check whether 

the steam pipe is smooth.

The light can not 

be turned on

The display box 

displays normally 

with no steam 

input

1. Too much pressure inside the steam 

engine, so the system breaks for 

heat protection.

2. Wire is broken for heat protection.

1. Check the steam transport pipe and 

restore automatically after heat 

protection becomes cool.

2. Check the heat protection wire to make 

sure the connection is good.

1. The fuse is burned.

2. The light is broken

3. The wire is broken

4. The plug does not have good contact

1. Change the fuse (on the shell 1A/250V)

2. Change a light bulb.

3. Change wire.

4. Cake the contact good.

GEN3-1

Summary of Contents for BAGNOSPA BDD-SPA-GEN3-1-A

Page 1: ...BDD SPA GEN3 1 A BAGNOSPA STEAM GENERATOR 3KW 220V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com...

Page 2: ...tion of the tube 3 Drawing of the steam generator 5 Electric requirements 6 Power line assemble illustration 8 Wiring Diagram 380 415V 3PH 9 Wiring Diagram 208V 3PH 10 Wiring Diagram 220 240V 1PH 2PH...

Page 3: ...link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of...

Page 4: ...let are still very heated after the steam generator have stopped working for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep...

Page 5: ...istant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape...

Page 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using w...

Page 7: ...GEN3 1 Blueprint for the steam engine...

Page 8: ...n independent circuit breaker between the power supply and the steam engine so as to provide an electricity supply with overflow protection and electricity leakage protection All the connection must b...

Page 9: ...ot connect strong electric current to the component directly GEN3 1 Assembly graph for power wire This graph is for explanation only For actual installation refer to national and local electricity con...

Page 10: ...GEN3 1 Wiring Diagram 380 415V 3PH 208V 3PH 220 240V 1PH 2PH...

Page 11: ...light should be installed on the top of the steam room or the places where are not access to the children C C A A U U T T I I O O N N C A UTIO N The illustration is just for explaination the practica...

Page 12: ...ghts exceeding 8 FT ADD 75 D Ceramic tile ADD 75 E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the t...

Page 13: ...it board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105OC Hi limit Transformer 11 12 Terminal block Fuse...

Page 14: ...ether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water...

Page 15: ...e ml min Steam Production Time S GEN3 1 TYPE GEN3 1 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank Volume 3KW 10 1500V 20M 0 12Pa 140 100 150...

Page 16: ...IND SPA GEN3 1 A 12 21 www sanipexgroup com...