Configuration / setup
November 2014
AC_F110_BA_02_1346
Page 5
6.
CONFIGURATION / SETUP
6.1
In general
•
Mounting, electrical installation, start-up and maintenance of the instrument may only be carried out by trained
personnel authorized by the operator of the facility. Personnel must read and understand this operating manual before
carrying out its instructions.
•
Personnel who are authorized and trained by the operator of the facility may only operate the F110. All instructions in this
manual are to be observed.
•
Ensure that the measuring system is correctly wired up according to the wiring diagrams. Only trained personnel may
open the housing.
•
Take careful notice of the "Safety rules, instructions and precautionary measures" in the leading chapters of this manual.
This chapter describes the daily use of the F110. These instructions are meant for users / operators.
6.2
SETUP level
Configuration of the F110 is done at SETUP level. SETUP level is reached by pressing the PROG/ENTER key
for 7 seconds; at which time, both arrows will be displayed. In order to return to the operator level,
PROG will have to be pressed for three seconds. Alternatively, if no keys are pressed for 2 minutes, the
unit will exit SETUP automatically. SETUP can be reached at all times while the F110 remains fully
operational.
Press
for 7 seconds to enter SETUP.
NOTE:
A pass code may be required to enter SETUP. Without this pass code access to SETUP is denied.
Matrix structure SETUP level