Example: Correction of the accuracy
Quantity dispensed: 1,6 l
Quantity displayed: 1,52 l
Correction factor k =
1,6/1,52 =
1,0526
a)
Display current correction factor by pressing and holding TOTAL and RESET buttons simultaneously.
Example: 0,9950 (Make a note of this number)
b)
Calculation of the new correction factor:
0,9950 x 1,0526 = 1,0473
c)
Press and hold program button until programming procedure is completed.
d)
Display will show the following data:
-
momentary correction factor
-
unit of measure (flashing)
e)
Press TOTAL button until right most correction factor digit that you wish to change begins to flash (in this case, 0).
f)
Press RESET button until desired digit appears (in this case, 9).
g)
Press TOTAL button until the next digit you wish to change begins to flash (in this case, the first 9).
h)
Press RESET button until desired digit appears (in this case, 8).
i)
Press TOTAL button until the next digit you wish to change begins to flash (in this case, the second 5).
j)
The register module can now be remounted on the meter.
Note: After programming, display will be blank. Press RESET button to re-activate the display.