Installation
Installing the Transmitter
1 Disconnect the electrical power from the target system before making or changing any
transmitter connections
2 Use 005 A fast-acting fuse if non-current limited power sources are used
3 Terminate cable shield connection at either DC ground or earth ground
4 Mount the transmitter so fluid is traveling in the direction of the flow arrow
Flow Direction Arrow
Flow Inlet
Figure 1: Flow direction arrow
5 Install unit in desired location Use wrench on transmitter flats to hold the unit in place
during installation DO NOT TURN the transmitter using the wrench
6 After installation, rotate the transmitter by hand to view the display
7 Capture the zero flow position on the meter cone using the ZERO CAPTURE procedure
Place wrench on transmitter flats on the
same side plumbing is being tightened
Never place wrench on transmitter flats
opposite plumbing being tightened
Rotate transmitter by hand only to view flow scale Never use wrench on flats to
rotate transmitter
Figure 2: Installing and rotating the transmitter