Badger Meter Hedland MR User Manual Download Page 38

Dimensions

DIMENSIONS

C

K

A

D

B

F E

G

J

H

I

Figure 24:  Dimensions

Nominal 

Port Size

B

C

D

E

F

G

H

I

J

K

Length 

in. (mm)

Length 

in. (mm)

Length 

in. (mm)

Width 

in. (mm)

Width 

in. (mm)

Width 

in. (mm)

Cable 

in. (mm)

Depth 

in. (mm)

Offset 

in. (mm)

Hole Dia. 

in. (mm)

1/4 in. 

SAE 6

6.60 

(167.64)

5.27 

(133.86)

6.92 

(175.77)

6.00 

(152.40)

3.60 

(91.44)

3.00 

(76.20)

4.20 

(107)

2.94 

(74.68)

1.46 

(37.08)

0.28 

(7.11)

1/2 in. 

SAE 10

6.60 

(167.64)

5.27 

(133.86)

6.92 

(175.77)

6.00 

(152.40)

3.60 

(91.44)

3.00 

(76.20)

4.20 

(107)

2.94 

(74.68)

1.46 

(37.08)

0.28 

(7.11)

3/4 in. 

SAE 12

7.20 

(182.88)

5.27 

(133.86)

6.92 

(175.77)

6.00 

(152.40)

3.60 

(91.44)

3.00 

(76.20)

4.20 

(107)

2.94 

(74.68)

1.46 

(37.08)

0.28 

(7.11)

1 in. 

SAE 16

7.20 

(182.88)

5.27 

(133.86)

6.92 

(175.77)

6.00 

(152.40)

3.60 

(91.44)

3.00 

(76.20)

4.20 

(107)

2.94 

(74.68)

1.46 

(37.08)

0.28 

(7.11)

1-1/4 in. 

SAE 20

12.20 

(309.88)

10.68 

(271.27)

11.65 

(295.91)

7.63 

(193.80)

4.84 

(122.94)

3.82 

(97.03)

5.02 

(128)

4.50 

(114.30)

2.20 

(55.88)

0.28 

(7.11)

1-1/2 in. 

SAE 24

12.20 

(309.88)

10.68 

(271.27)

11.65 

(295.91)

7.63 

(193.80)

4.84 

(122.94)

3.82 

(97.03)

5.02 

(128)

4.50 

(114.30)

2.20 

(55.88)

0.28 

(7.11)

Table 12: Dimensions

OTEE:

N

Fractional sizes apply to NPT and BSP configurations

Page 38 

September 2017

XMT-UM-00498-EN-03

Summary of Contents for Hedland MR

Page 1: ...Flow Transmitter MR Model XMT UM 00498 EN 03 September 2017 User Manual...

Page 2: ...ncludes Caustic Corrosive Gases 14 Programming Procedures 15 List Item Selection Procedure 15 Numeric Value Entry Procedure 15 Programming Flowcharts 16 Cartridge Components 20 Maintenance 21 Cartridg...

Page 3: ...ibrated from the factory However the unit may be adjusted by the user to meet specific system requirements Calibration parameters are included for Specific gravity compensation all fluids Viscosity co...

Page 4: ...FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH AND OR DAMAGE TO THE EQUIPMENT AIR GAS METERS ARE NOT OXYGEN CLEANED USE WITH OXYGEN MAY CAUSE HAZARDOUS OR EXPLOSIVE CONDITI...

Page 5: ...llow particulate to pass that would jam most valves and flow controls Systems that do not have filtration should be equipped with at least a 200 mesh 74 micron filter Most hydraulic systems already ha...

Page 6: ...ll unit in desired location Use wrench on transmitter flats to hold the unit in place during installation DO NOT TURN the transmitter using the wrench 6 After installation rotate the transmitter by ha...

Page 7: ...e it Rotate the cable connector 90 degrees and try again until it seats When the connector is fully seated use a Philips screwdriver to tighten it Black Green Red White Ground Black 2 Green 3 White 4...

Page 8: ...d by either AC power or DC supply Figure 7 and Figure 8 on page 9 are used when the flow transmitter is operated with loop powered process indicators or data loggers that do not have external sensor e...

Page 9: ...C Input Figure 8 0 5V DC or 0 10V DC connection using target s external power supply Cover Removal Reinstallation You must remove the MR flow transmitter cover to access the programming keys Use a Phi...

Page 10: ...ow alternate being shown as the default The meter can also be set to show only flow rate or only flow total MENU ENTER Programming Buttons Figure 10 Programming buttons In RUN mode the four programmin...

Page 11: ...e indicator on the display changes from RUN to PROGRAM Scrolls through the configuration choices in a bottom to top order For numeric setup this button increments numeric values Scrolls through the co...

Page 12: ...interval RateUnt Rate Unit Gallons Liters Million Gallons Cubic Feet Cubic Meters Million Liters Acre Feet Oil Barrel Liquor Barrel Pounds Kilograms TotalUnt Totalizer Unit Gallons Liters Million Gall...

Page 13: ...erval RateUnt Rate Unit Gallons Liters Million Gallons Cubic Feet Cubic Meters Million Liters Acre Feet Oil Barrel Liquor Barrel Pounds Kilograms TotalUnt Totalizer Unit Gallons Liters Million Gallons...

Page 14: ...V Numeric Entry 0 10 Test Test Output Single Digit Increments Res Dflt Reset to Default Op Pres Operating Pressure Numeric Entry Op Temp OperatingTemperature Numeric Entry Sp Grav Specific Gravity Num...

Page 15: ...press MENU The display changes to RUN mode Numeric Value Entry Procedure NOTE N If you are already in PROGRAM mode and the selection to view or change is displayed proceed to step 3 below If you are i...

Page 16: ...E INT The meter lets you select intervals based on time Edit with the List Item Selection Procedure on page 15 Total Units of Measure TOTL UNT To display the Total Flow you must first select the engin...

Page 17: ...n with Viscosity to perform viscosity correction for oil applications You can select the viscosity units SUS or cSt Edit with the List Item Selection Procedure on page 15 Viscosity VISCOSITY Displayed...

Page 18: ...e of the gas being measured at the meter Enter the operating temperature in either F or C depending on the Operating Temperature Units selected Edit with the List Item Selection Procedure on page 15 S...

Page 19: ...he flowcharts on pages page 12 through page 14 To test or change the analog output calibration 1 At the CAL OUT prompt press ENTER NO displays 2 Press either arrow key to select YES 3 The analog outpu...

Page 20: ...ic Value Entry Procedure on page 20 Restore Defaults RES DFLT Use this feature to restore factory calibration data To restore factory calibration data select YES then press ENTER CARTRIDGE COMPONENTS...

Page 21: ...inlet port wave spring retaining ring and cone from the body see Figure 14 Cartridge components on page 20 5 Using the end fitting flats clamp the outlet end fitting then remove the inlet end fitting...

Page 22: ...ew tightening sequence on page 9 13 Reinstall the flow meter in the line Reconnect the transmitter cable Inspection Inspect the transmitter at least once a year The environment and frequency of use sh...

Page 23: ...tering in order to provide a more stable display reading APPLICATION INFORMATION Liquid Viscosity Effect SUS cSt The design uses a precision machined sharp edged orifice and biasing calibration spring...

Page 24: ...175 200 225 250 BAR 1 7 3 5 5 2 6 9 8 6 10 4 12 1 13 8 15 5 17 2 kPa 172 345 517 689 862 1034 1207 1379 1551 1724 f1 1 700 1 331 1 131 1 00 0 902 0 835 0 778 0 731 0 692 0 658 f kPa 1 790 857 101 357...

Page 25: ...Gasoline 0 70 1 119 1 195 R R R R R N C R R Glycerin 1 26 0 834 0 891 R R R R R R R C R Kerosene 0 82 1 033 1 104 R R R R R N R R R Liquid Propane LPG 0 51 1 310 1 400 R R R R R N N R R Mineral Oil 0...

Page 26: ...11 CCI3 F 4 92 2 218 R R R R R R R R R Freon 12 CCI2 F 4 26 2 060 R R R R R R R R R Helium HE 0 14 0 374 R R R R R R R R R Hydrogen H2 0 07 0 265 R R R R R R R R R Natural Gas 0 60 0 775 C C R C R N...

Page 27: ...ROP PSI 3 4 1 5 50 4 40 3 30 2 20 1 2 Reverse Flow 0 1 1 0 0 5 5 0 0 2 2 0 1 10 1 15 FLOW GPM PRESSURE DROP PSI 0 2 2 0 0 5 10 0 10 1 10 0 5 5 0 Figure 16 Petroleum fluids pressure drop charts The pre...

Page 28: ...0 20 2 0 0 10 1 0 1 2 Reverse Flow 0 1 1 0 0 5 5 0 0 2 2 0 1 10 1 15 FLOW GPM PRESSURE DROP PSI 3 4 1 Reverse Flow 0 2 2 0 0 5 5 0 1 10 2 20 3 30 4 40 FLOW GPM PRESSURE DROP PSI 1 1 4 1 1 2 Reverse Fl...

Page 29: ...10 1 0 20 2 0 1 15 1 10 0 5 5 0 0 2 2 0 FLOW GPM PRESSURE DROP PSI 1 2 3 4 1 4 40 3 30 2 20 FLOW GPM PRESSURE DROP PSI 1 1 4 1 1 2 10 100 10 75 5 50 3 30 FLOW GPM PRESSURE DROP PSI Figure 18 API oil p...

Page 30: ...20 3 30 4 40 FLOW GPM PRESSURE DROP PSI 3 20 275 20 180 FLOW GPM PRESSURE DROP PSI 1 1 4 1 1 2 10 150 10 100 10 75 5 50 3 30 FLOW GPM PRESSURE DROP PSI 1 15 1 10 FLOW GPM PRESSURE DROP PSI 1 2 0 5 5...

Page 31: ...0 3 30 FLOW GPM PRESSURE DROP PSI 1 4 10 1 0 20 2 0 FLOW GPM PRESSURE DROP PSI 1 15 1 10 FLOW GPM PRESSURE DROP PSI 1 2 0 5 5 0 3 4 1 5 50 4 40 3 30 2 20 FLOW GPM PRESSURE DROP PSI 0 5 5 0 1 10 0 2 2...

Page 32: ...M PRESSURE DROP PSI 1 4 10 1 0 20 2 0 FLOW GPM PRESSURE DROP PSI 3 4 1 4 40 3 30 2 20 FLOW GPM PRESSURE DROP PSI 1 15 1 10 FLOW GPM PRESSURE DROP PSI 1 2 0 5 5 0 0 2 2 0 0 5 5 0 1 10 0 1 2 0 Figure 21...

Page 33: ...SI 1 1 4 1 1 2 0 5 10 15 20 25 30 0 400 200 600 800 1000 20 200 60 600 80 800 100 1000 40 400 FLOW SCFM PRESSURE DROP PSI 1 2 0 5 10 15 20 0 50 25 75 100 125 150 3 25 15 150 10 100 5 50 FLOW SCFM PRES...

Page 34: ...ROP PSI 1 1 4 1 1 2 0 5 10 15 20 25 30 0 400 200 600 800 1000 20 200 60 600 80 800 100 1000 40 400 FLOW SCFM PRESSURE DROP PSI 1 2 0 5 10 15 20 0 50 25 75 100 125 150 3 25 15 150 10 100 5 50 FLOW SCFM...

Page 35: ...rement 0 5V DC Output 10 30V DC 0 75W maximum 0 10V DC Output 12 30V DC 0 75W maximum 4 20 mA Output loop powered 30V DC maximum Power Consumption 25 mA maximum Analog Outputs 0 5V DC and 0 10V DC int...

Page 36: ...Spider Plate Retaining Ring Spring Retaining Spring Fasteners Internal Magnet Pressure Seals Enclosure Seal Lens T316 SS SAE 1070 1090 Carbon Steel 302 SS SAE 1070 1090 Carbon Steel T303 SS Teflon Coa...

Page 37: ...and establishing the burst pressure ratings of the pressure containing envelope of a metal fluid power component Meter Size Aluminum Brass Stainless Steel RFP Cycles RFP Cycles RFP Cycles 1 4 2000 1...

Page 38: ...8 1 46 37 08 0 28 7 11 3 4 in SAE 12 7 20 182 88 5 27 133 86 6 92 175 77 6 00 152 40 3 60 91 44 3 00 76 20 4 20 107 2 94 74 68 1 46 37 08 0 28 7 11 1 in SAE 16 7 20 182 88 5 27 133 86 6 92 175 77 6 00...

Page 39: ...INTENTIONAL BLANK PAGE User Manual September 2017 XMT UM 00498 EN 03 Page 39...

Page 40: ...71 4 371 2503 Slovakia Badger Meter Slovakia s r o Racianska 109 B 831 02 Bratislava Slovakia 421 2 44 63 83 01 Asia Pacific Badger Meter 80 Marine Parade Rd 21 06 Parkway Parade Singapore 449269 65 6...

Reviews: