Specifications

Page 11 

June 2020

TRB-UM-00287-EN-07

SPECIFICATIONS

Materials of 

Construction

Body

316/316L stainless steel

Rotor

CD4MCu stainless steel

Bearings

Tungsten carbide

Rotor Shaft

Tungsten carbide

Rotor Support

316L

Operating 

Temperature

–150…350° F (–101…177° C) standard 

Temperatures to 450° F (232° C) with high-temp pickup, consult factory for 

details 

The standard meter should not be subjected to temperatures above 350° F  

(177° C), or below –150° F (–101° C) or the freezing point of the metered liquid�

Pressure Rating

See 

"Pressure Rating" 

below

End Connections

Wafer-Style ASME/ANSI B16�5-1996

Turndown Ratio

Accuracy

± 1�0% of reading

Repeatability

± 0�1%

Calibration

Water; NIST Traceable Calibration, Certificate available, consult factory for details

Pickup

B111109, B220111, B220210, B220243, B111126

Conformance

NACE MR0175/ISO 15156

Pressure 

Standards/

Approvals

Canadian Registration Number (CRN), PED 2014/68/EU, Group 1, Category II

Pulsation and 

Vibration

Severe pulsation and mechanical vibration will affect accuracy and shorten the 

life of the meter�

Certifications

Class I Div� I Groups C,D Complies to UL1203 and CSA 22�2 No� 30 Met Labs File 

No� E112860

Pressure Rating

The pressure rating of the meter is dependent upon the class of ANSI flanges 

between which the meter is to be mounted� The pressure rating chart below is 

based on Carbon Steel at 100° F (37�8° C)�

Flange Class (ANSI)

150#

300#

600#

900#

1 1500#

Working Pressure (psi)

285

740

1480

2220

3705

Working Pressure (bar)

20

51

102

153

256

Working Pressure (MPa)

1�97

5�10

10�20

15�31

25�55

2 Test Pressure (psi)

427�5

1110

2220

3330

5557�5

2 Test Pressure (MPa)

2�95

7�65

15�31

22�98

38�32

1

 

For bore size 2 in� and less

2

 

Test pressure based on 1�5 safety factor

Summary of Contents for Blancett B133C-380

Page 1: ...Turbine Flow Meter QuikSert Explosion Proof TRB UM 00287 EN 07 June 2020 User Manual...

Page 2: ...Turbine Flow Meter QuikSert Explosion Proof Page ii June 2020 TRB UM 00287 EN 07...

Page 3: ...ction 5 Operating Principle 5 Installation 7 Operational Startup 9 Troubleshooting Guide 10 Specifications 11 Pressure Rating 11 Meter Parts 12 Part Number Information Pickup Not Included 13 Flow Rang...

Page 4: ...age that may have occurred during shipment OTE N If damage is found request an inspection by the carrier s agent within 48 hours of delivery and file a claim with the carrier A claim for equipment dam...

Page 5: ...ts volumetric flow rate With optional Blancett electronics QuikSert provides local flow rate and volume totalization and will interface with most instruments PLCs and computers OPERATING PRINCIPLE Flu...

Page 6: ...TRB UM 00287 EN 07 Figure 2 Etching OTE N For easy reference the meter specifications that include part number serial number maximum working pressure and minimum and maximum operating temperature are...

Page 7: ...fittings suitable for the installation area onto the conduit adapter hub on the flow meter The liquid being measured should be free of any large particles that may obstruct rotation of the rotor If pa...

Page 8: ...meter accuracy may be affected Piping should be the same size as the meter bore or threaded port size Do not locate the flow meter or connection cable close to electric motors transformers sparking d...

Page 9: ...alve Flow liquid through the bypass valve for sufficient time to eliminate any air or gas in the flow line HIGH VELOCITY AIR OR GAS MAY DAMAGE THE INTERNAL COMPONENTS OF THE METER 2 Open upstream isol...

Page 10: ...tor shows flow when shut off Mechanical vibration causes rotor to oscillate without turning Isolate meter No flow indication Full or partial open position Fluid shock full flow into dry meter or impac...

Page 11: ...p B111109 B220111 B220210 B220243 B111126 Conformance NACE MR0175 ISO 15156 Pressure Standards Approvals Canadian Registration Number CRN PED 2014 68 EU Group 1 Category II Pulsation and Vibration Sev...

Page 12: ...Pickup Not Included Rotor Support Meter Body Conduit Adapter Retaining Ring Figure 5 Typical cross section of models B131C 038 B131C 100 Rotor Assembly Thrust Ball Bushing Magnetic Pickup Not Include...

Page 13: ...139C 900 10 10 Coming soon 4 1 6 10 Flow Range Chart Part Number Flow Ranges gpm lpm bpd m3 d B131C 038 0 60 3 00 2 27 11 36 20 100 3 3 16 B131C 050 0 75 7 50 2 84 28 39 25 250 4 1 41 B131C 075 2 00 1...

Page 14: ...Repair Kit Part Number Max Pressure Drop Dimensions Diameter Length in mm B131C 038 B253 102 3 75 psi 2 4 50 4 101 6 B131C 050 B253 105 6 5 psi 2 4 50 4 101 6 B131C 075 B253 108 18 psi 2 4 50 4 101 6...

Page 15: ...INTENTIONAL BLANK PAGE User Manual June 2020 TRB UM 00287 EN 07 Page 15...

Page 16: ...t are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without noti...

Reviews: