Strainer Recommendations

Part Number

Strainer Mesh

Clearance (in.)

Filter Size

B131C-038

60

0�0092

260 Micron

B131C-050

60

0�0092

260 Micron

B131C-075

60

0�0092

260 Micron

B131C-088

60

0�0092

260 Micron

B131C-100

60

0�0092

260 Micron

B132C-050

60

0�0092

260 Micron

B132C-075

60

0�0092

260 Micron

B132C-088

60

0�0092

260 Micron

B132C-100

40

0�0150

400 Micron

B132C-150

20

0�0340

0�86

B132C-200

20

0�0650

0�86

B132C-250

10

0�0900

1�6

B133C-300

10

0�0900

1�6

B133C-380

10

0�0900

1�6

B134C-400

10

0�0650

1�6

B136C-600

4

0�1875

4�8

B138C-800

4

0�0900

4�8

B139C-900

4

0�0900

4�8

Repair Kit Information

Repair Kit Fits Meter Part 

Number

Repair Kit Part 

Number

Max. Pressure Drop

Dimensions 

Diameter × Length 

in. (mm)

B131C-038

B253-102

3�75 psi

2 × 4 (50�4 × 101�6)

B131C-050

B253-105

6�5 psi

2 × 4 (50�4 × 101�6)

B131C-075

B253-108

18 psi

2 × 4 (50�4 × 101�6)

B131C-088

B253-109

20 psi

2 × 4 (50�4 × 101�6)

B131C-100

B253-112

20 psi

2 × 4 (50�4 × 101�6)

B132C-050

B253-205

12 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-075

B253-208

18 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-088

B253-209

20 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-100

B253-212

20 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-150

B253-216

16 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-200

B253-220

9 psi

3�62 × 2�5 (91�9 × 63�5)

B132C-250

B253-220

10 psi

5 × 4�25 (127 × 108)

B133C-300

B253-330

10 psi

5 × 4�25 (127 × 108)

B133C-380

B253-330

10 psi

5 × 4�25 (127 × 108)

B134C-400

B253-440

10 psi

6�18 × 5 (157 × 127)

B136C-600

B253-660

10 psi

8�5 × 5�75 (215�9 × 146�1)

B138C-800

B253-880

10 psi

10�62 × 6�25 (269�7 × 158�8)

B139C-900

B253-990

10 psi

12�75 × 6�75 (323�8 × 171�4)

All Meter Sizes

B111109

Standard Magnetic Pickup

Summary of Contents for Blancett B133C-380

Page 1: ...Turbine Flow Meter QuikSert Explosion Proof TRB UM 00287 EN 07 June 2020 User Manual...

Page 2: ...Turbine Flow Meter QuikSert Explosion Proof Page ii June 2020 TRB UM 00287 EN 07...

Page 3: ...ction 5 Operating Principle 5 Installation 7 Operational Startup 9 Troubleshooting Guide 10 Specifications 11 Pressure Rating 11 Meter Parts 12 Part Number Information Pickup Not Included 13 Flow Rang...

Page 4: ...age that may have occurred during shipment OTE N If damage is found request an inspection by the carrier s agent within 48 hours of delivery and file a claim with the carrier A claim for equipment dam...

Page 5: ...ts volumetric flow rate With optional Blancett electronics QuikSert provides local flow rate and volume totalization and will interface with most instruments PLCs and computers OPERATING PRINCIPLE Flu...

Page 6: ...TRB UM 00287 EN 07 Figure 2 Etching OTE N For easy reference the meter specifications that include part number serial number maximum working pressure and minimum and maximum operating temperature are...

Page 7: ...fittings suitable for the installation area onto the conduit adapter hub on the flow meter The liquid being measured should be free of any large particles that may obstruct rotation of the rotor If pa...

Page 8: ...meter accuracy may be affected Piping should be the same size as the meter bore or threaded port size Do not locate the flow meter or connection cable close to electric motors transformers sparking d...

Page 9: ...alve Flow liquid through the bypass valve for sufficient time to eliminate any air or gas in the flow line HIGH VELOCITY AIR OR GAS MAY DAMAGE THE INTERNAL COMPONENTS OF THE METER 2 Open upstream isol...

Page 10: ...tor shows flow when shut off Mechanical vibration causes rotor to oscillate without turning Isolate meter No flow indication Full or partial open position Fluid shock full flow into dry meter or impac...

Page 11: ...p B111109 B220111 B220210 B220243 B111126 Conformance NACE MR0175 ISO 15156 Pressure Standards Approvals Canadian Registration Number CRN PED 2014 68 EU Group 1 Category II Pulsation and Vibration Sev...

Page 12: ...Pickup Not Included Rotor Support Meter Body Conduit Adapter Retaining Ring Figure 5 Typical cross section of models B131C 038 B131C 100 Rotor Assembly Thrust Ball Bushing Magnetic Pickup Not Include...

Page 13: ...139C 900 10 10 Coming soon 4 1 6 10 Flow Range Chart Part Number Flow Ranges gpm lpm bpd m3 d B131C 038 0 60 3 00 2 27 11 36 20 100 3 3 16 B131C 050 0 75 7 50 2 84 28 39 25 250 4 1 41 B131C 075 2 00 1...

Page 14: ...Repair Kit Part Number Max Pressure Drop Dimensions Diameter Length in mm B131C 038 B253 102 3 75 psi 2 4 50 4 101 6 B131C 050 B253 105 6 5 psi 2 4 50 4 101 6 B131C 075 B253 108 18 psi 2 4 50 4 101 6...

Page 15: ...INTENTIONAL BLANK PAGE User Manual June 2020 TRB UM 00287 EN 07 Page 15...

Page 16: ...t are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without noti...

Reviews: