Badger Meter B280-737 User Manual Download Page 16

www.badgermeter.com

BLANCETT is a registered trademark of Badger Meter, Inc  Other trademarks appearing in this document are the property of their respective entities  Due to continuous research, 

product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding 

contractual obligation exists  © 2017 Badger Meter, Inc  All rights reserved  

Control. Manage. Optimize.

Flow Monitor, B2800XP Explosion Proof Flow Monitor Standard

The Americas | Badger Meter

 | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V.

 | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Eastern Europe Branch Office

 

(for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus)

 | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787

Europe, Middle East and Africa | Badger Meter Europa GmbH

 | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe

 | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 

Slovakia | Badger Meter Slovakia s.r.o. 

| Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter

 | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter

 | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Switzerland | Badger Meter Swiss AG

 | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11 

Legacy Document Number: 02-DSY-PM-00114

Summary of Contents for B280-737

Page 1: ...Flow Monitor B2800XP Explosion Proof Flow Monitor Standard DSY PM 00277 EN 03 March 2017 User Manual...

Page 2: ...s 7 Modes 7 Programming 8 Programming Mode 8 Run Mode 9 Additional Scaling Parameters 10 Flow 4 mA Setting 10 Flow 20 mA Setting 10 4 20 mA Calibration 10 4 20 mA Test 10 Additional Input Options 11 B...

Page 3: ...serious personal injury Indicates a hazardous situation which if not avoided could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be ca...

Page 4: ...provides for selectable units viewing in run mode and prompts for variables in program mode The display can show rate total or alternate between both rate and total Programming Buttons MENU ENTER EXPL...

Page 5: ...amage to the cover threads and glass lens when glass lens cover is used 5 Pull wires into enclosure making certain they are long enough to make the required connections and to remove the instrument or...

Page 6: ...kits are available Hub Size Kit Number Meter Sizes 1 2 in NPT Hub B280 742 3 8 in 1 2 in 3 4 in with 1 2 in NPT End Fittings 1 in NPT Hub B280 737 All Sizes with 1 in NPT End Fittings and Larger Insta...

Page 7: ...programming the display with the necessary information turn on the lock out feature to prevent unauthorized access or changing the meter s setup parameters MENU ENTER Buttons MENU Switches to PROGRAM...

Page 8: ...and the bore size are different For example many of the one inch NPT turbines have bore sizes that range from 3 8 1 in Be sure to use the correct bore size or the meter will report incorrect flows and...

Page 9: ...e Initially the password is set to all zeros and any user can modify the parameter settings in PROGRAM mode To change the password enter any four digit code Press UP to increment the digit and RIGHT t...

Page 10: ...tting is typically between 35 50 To set the 4 mA value connect an ammeter in series with the loop power supply At the 4MA OUT prompt press UP to increment and RIGHT to decrement the 4 mA value to unti...

Page 11: ...ttery Power Loop Power BATTERY REPLACEMENT Battery powered monitors use a single 1 5V D size alkaline battery When replacement is necessary use a clean fresh battery for continued trouble free operati...

Page 12: ...r 2 Perform visual electrical and mechanical checks on all components on a regular basis a Visually check for undue heating evidenced by discoloration of wires or other components damaged or worn part...

Page 13: ...nitor pig tail This should stop the noise If not then try reorientating the meter to a new location Flow rate indicator bounces This usually indicates a weak signal Replace pickup and or check all con...

Page 14: ...drop 0 1 A Magnetic Pickup Inputs Frequency Range 0 3500 Hz Trigger Sensitivity 30 mV p p Over Voltage Protected 30V DC Frequency Measurement Accuracy 0 1 Temperature Drift 50 ppm C maximum Optional...

Page 15: ...2 6 in 9 84 mm 5 16 in 1 19 mm 4 51 in 17 07 mm PART NUMBER INFORMATION Program Level S B 28 S X X X X Power Option B Battery L Loop Mounting Style X Explosion proof Units of Measure AB Gallons ED Bar...

Page 16: ...Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur...

Reviews: