Suggested Operating 

Pipe Size 

Pipe O.D. 

Pipe I.D. 

K Value 

Offset 

Range (GPM) 

14 inch Sch 10S

14.00" 

13.500" 

122.307 

0.391 

200-6,000 

Sch 20 

14.00" 

13.375" 

120.216 

0.388 

200-6,000 

Std. Wt., Sch 30 

14.00" 

13.250" 

118.151 

0.385 

200-6,000 

Sch 40 

14.00" 

13.124" 

116.096 

0.382 

200-6,000 

Sch 60 

14.00" 

12.814" 

111.148 

0.376 

200-6,000 

Extra Strong 

14.00" 

13.00" 

114.098 

0.33 

200-6,000 

Sch 80 

14.00" 

12.50" 

106.299 

0.369 

200-6,000 

16 inch Sch 10S

16.00" 

15.500" 

159.243 

0.44 

300-9,000 

Sch 20 

16.00" 

15.375" 

156.742 

0.436 

300-9,000 

Std. Wt., Sch 30 

16.00" 

15.250" 

154.267 

0.433 

300-9,000 

Sch 60 

16.00" 

14.688" 

143.456 

0.419 

300-9,000 

Extra Strong, Sch 40 

16.00" 

15.000" 

149.394 

0.427 

300-9,000 

Sch 80 

16.00" 

14.314" 

136.548 

0.41 

300-9,000 

18 inch Sch 10S

18.00" 

17.500" 

202.739 

0.498 

350-10,000 

Sch 20 

18.00" 

17.375" 

199.828 

0.494 

350-10,000 

Sch 30 

18.00" 

17.124" 

194.061 

0.486 

350-10,000 

Std. Wt. 

18.00" 

17.250" 

196.943 

0.49 

350-10,000 

Sch 40 

18.00" 

16.876" 

188.464 

0.479 

350-10,000 

Sch 60 

18.00" 

16.500" 

180.171 

0.469 

350-10,000 

Extra Strong 

18.00" 

17.000" 

191.25 

0.482 

350-10,000 

Sch 80 

18.00" 

16.126" 

172.152 

0.457 

350-10,000 

20 inch Std. Wt., Sch 20

20.00" 

19.25" 

246.179 

0.555 

400-12,000 

Sch 40 

20.00" 

18.812" 

234.836 

0.540 

400-12,000 

Extra Strong, Sch 30 

20.00" 

19.000" 

239.666 

0.547 

400-12,000 

Sch 80 

20.00" 

17.938" 

213.14 

0.511 

400-12,000 

22 inch Std. Wt., Sch 20

22.00" 

21.25" 

301.975 

0.621 

500-15,000 

Extra Strong, Sch 30 

22.00" 

21.00" 

294.642 

0.616 

500-15,000 

Sch 80 

22.00" 

19.75" 

259.513 

0.573 

500-15,000 

24 inch Std. Wt., Sch 20

24.00" 

23.25" 

364.331 

0.666 

600-18,000 

Extra Strong 

24.00" 

23.00" 

356.178 

0.660 

600-18,000 

Sch 40 

24.00" 

22.624" 

344.109 

0.652 

600-18,000 

Sch 80 

24.00" 

21.562" 

311.271 

0.628 

600-18,000 

26 inch Sch 10

26.00" 

25.376" 

437.809 

0.719 

700-21,000 

Std. Wt. 

26.00" 

25.25" 

433.247 

0.716 

700-21,000 

Sch 20, Extra Strong 

26.00" 

25.00" 

424.274 

0.709 

700-21,000 

28 inch Sch 10

28.00" 

27.376" 

513.698 

0.774 

900-23,000 

Std. Wt. 

28.00" 

27.25" 

508.723 

0.770 

900-23,000 

Extra Strong, Sch 20 

28.00" 

27.00" 

498.930 

0.763 

900-23,000 

30 inch Sch 10

30.00" 

29.376" 

596.147 

0.833 

1,000-30,000 

Std. Wt. 

30.00" 

29.25" 

590.759 

0.829 

1,000-30,000 

Sch 20, Extra Strong 

30.00" 

29.00" 

580.146 

0.822 

1,000-30,000 

32 inch Sch 10

32.00" 

31.376" 

685.156 

0.897 

1,200-35,000 

Std. Wt. 

32.00" 

31.25" 

679.355 

0.893 

1,200-35,000 

Sch 20, Extra Strong 

32.00" 

31.00" 

667.922 

0.885 

1,200-35,000 

Sch 40 

32.00" 

30.624" 

650.919 

0.873 

1,200-35,000 

34 inch Sch 10

34.00" 

33.312" 

777.566 

0.964 

1,300-40,000 

Std. Wt. 

34.00" 

33.25" 

774.511 

0.962 

1,300-40,000 

Extra Strong, Sch 20 

34.00" 

33.00" 

762.258 

0.953 

1,300-40,000 

Sch 40 

34.00" 

32.624" 

744.022 

0.940 

1,300-40,000 

36 inch Sch 10

36.00" 

35.376" 

882.855 

1.040 

1,500-45,000 

Std. Wt. 

36.00" 

35.25" 

876.227 

1.035 

1,500-45,000 

Sch 20, Extra Strong 

36.00" 

35.00" 

863.154 

1.025 

1,500-45,000 

Sch 40 

36.00" 

34.50" 

837.315 

1.007 

1,500-45,000 

 

Calibration Table for Pipe Sizes 3 Inches Through 36 Inches

Page 11 

August 2012

Summary of Contents for 220BR

Page 1: ...Series 200 Insertion Style Flow Sensors Installation Operation Manual 872020 EN August 2012 Rev 8 IMPORTANT This manual contains important information READ AND KEEP FOR REFERENCE...

Page 2: ...and 226SS 4 If the Pipe is Depressurized and Drained 5 INSTALLATION INTO A PRESSURIZED PIPELINE USING MODEL HTT 5 ELECTRICAL INSTALLATION STANDARD SENSORS 6 ELECTRICAL INSTALLATION IR SENSORS 6 ELECTR...

Page 3: ...eter impeller flow monitor or transmitter Badger Meter non magnetic flow sensors provide an accurate rate of liquid flow as well as total accumulated flow A number of sensor models are offered which c...

Page 4: ...ure removal of sensor for service or cleaning if necessary HOT TAP INSTALLATION FOR 225BR 226BR AND 226SS Badger Meter Series 200 hot tap style liquid flow sensors are designed for use in cases where...

Page 5: ...flow sensor tube into the hex mounting adapter The sleeve should be inserted past the top two O rings in the adapter approx 1 to 1 1 4 inches Take care not to push the tube in too far as the impeller...

Page 6: ...wo remaining lock nuts down until they just contact the positioning collar Do not tighten at this time 8 Remove the Model HTT Insertion Removal Tool by loosening the two thumbscrews removing the clevi...

Page 7: ...or transmitter locate the section of terminal strip on the monitor labeled SENSOR INPUT or SENSOR Connect the red wire to IN SIGNAL or SIGNAL terminal and the black wire to GND SIGNAL or COM terminal...

Page 8: ...Series 200 Flow Sensors Page 8 August 2012...

Page 9: ...ndards Columns 4 and 5 The K value and Offset that should be used in our frequency equation Freq Gpm K Offset This equation describes the frequency of the output signal of all Badger Meter flow sensor...

Page 10: ...8 071 41 063 0 283 80 2 500 Std Wt Sch 40 8 625 7 981 40 086 0 281 80 2 500 Sch 60 8 625 7 813 38 288 0 279 80 2 500 Extra Strong Sch 80 8 625 7 625 36 315 0 276 80 2 500 PVC Class 125 8 625 8 095 41...

Page 11: ...11 400 12 000 22 inch Std Wt Sch 20 22 00 21 25 301 975 0 621 500 15 000 Extra Strong Sch 30 22 00 21 00 294 642 0 616 500 15 000 Sch 80 22 00 19 75 259 513 0 573 500 15 000 24 inch Std Wt Sch 20 24 0...

Page 12: ...tion the impeller in the cavity oriented as in step 4 so that the impeller blades point into the flow direction and toward the small alignment hole located beside one of the sighting holes on metal se...

Page 13: ...00 hex adapter valve bronze UNS C83600 Sensor Sleeve and Hex Adapter for 220SS and 226SS Series 300 stainless steel Temperature Ratings Standard version 2210F 1050C continuous service High temperature...

Page 14: ...Series 200 Flow Sensors This page intentionally left blank Page 14 August 2012...

Page 15: ...Installation Operation Manual This page intentionally left blank Page 15 August 2012...

Page 16: ...6 800 876 3837 414 355 0400 M xico Badger Meter de las Americas S A de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Middle East a...