Section 5. Operating Instructions
5.1. IAM-100
Operation
State
Operating Instructions
Power Up
On power up there is an initial warm-up delay of 5
minutes, during which the green LED will flash at 1
second intervals. After warm-up, the green LED
remains on (constant).
Fault
Condition
Fault condition:
•
the green LED will be off
•
the red LED will be on
•
external interface to the optional IAM Controller
panel will activate and show the fault condition on
that panel
Alarm
Condition
In alarm condition:
•
the green LED stays on.
•
the red LED will be on.
•
the buzzer sounds (if it has not been disabled and
after a delay if this option has been selected).
•
the relay output activates (after a delay if this
option has been selected).
•
external interface to the optional IAM Controller
will be turned on.
•
The mute button on the exterior of the case may
be pressed. (This will switch the buzzer off if the
buzzer disable option is not selected).
•
The reset button is accessible via a hole in the
front panel, to the left of the green LED. This may
be pressed to reset the alarm if the manual reset
option is enabled (reset is only effective when the
gas has cleared from around the sensor, indicated
by the red LED turning off). A non-metallic object
(e.g., match or toothpick) should be used to
operate the reset button.
•
If automatic reset is enabled, the alarm will reset
by itself without user intervention.
Summary of Contents for IAM-100
Page 7: ...IAM 100 and Controller Manual 6209 9000 Rev 2 7 Figure 3 Sample Architecture Diagram ...
Page 14: ...IAM 100 and Controller Manual 14 6209 9000 Rev 2 Figure 6 Controller Housing ...
Page 34: ...IAM 100 and Controller Manual 34 6209 9000 Rev 2 ...
Page 35: ...IAM 100 and Controller Manual 6209 9000 Rev 2 35 ...