Section 7. Troubleshooting
IAM
Symptom
Possible Cause(s)
Green and
Red LEDs off
•
Check power supply. Check wiring.
•
IAM was possibly damaged in transit. Check by
installing another IAM on the same power source
to confirm the fault.
Red LED on,
green LED off
(indicates a
fault)
•
Sensor may be disconnected from PCB. Check
to see sensor element is properly inserted into
board.
•
The sensor has been damaged or has reached
the end of life and needs to be exchanged.
Contact Bacharach for instructions and support.
•
Check the remote cable between the main PCB
and the remote sensor PCB to ensure the
continuity.
Alarms in the
absence of a
leak
•
Ensure there are no background gases present in
the ambient air.
•
Ensure there are no cross-sensitive materials in
use during the alarm.
IAM-C
Symptom
Possible Cause(s)
Green LED off
•
Check power supply. Check wiring.
•
IAM-C was possibly damaged in transit. Check by
installing another IAM-C to confirm.
All 16 red
LEDs on a
master panel
are flashing
every 5
seconds
•
Remove the link on Jumper position HD3 as this
should be in the disabled position on a master
panel (factory default setting is disabled).