Some geometries will prevent the isopropyl from reaching all the liquid resin. These geometries 

will hold the air that gets trapped when the isopropyl rises to the print. To completely clean the 

print, remove the print from the Build Table and place it on the basket in the B9Clean and start 

another wash cycle. 

 

7.7.8

 

Ensure the printed part is dry and free of surface resin. It is recommended to use compressed 

air to dry pieces prior to Curing if necessary. 

 

7.8 

B9Clean Cleaning Procedure 

7.8.1

 Unplug the barrel jack from the back of the unit. 

7.8.2

 Remove container assembly from the base. 

7.8.3

 Inspect base for any resin. Clean with a cloth and isopropyl alcohol while observing personal 

protective measures (see chapt. 2.5).  

7.8.4

 Remove Lid and Inner Assembly container and set aside. 

7.8.5

 Remove all Isopropanol alcohol from the container. 

7.8.6

 Clean the inner and outer container surfaces with a clean cloth and isopropanol alcohol. 

7.8.7

 Inspect inner container bottom gasket to assure it is not damaged, replace if necessary. 

7.8.8

 Do not discard the stir bar and the drain plugs. 

 

Safety 

8.1 Isopropyl Alcohol Draining 

To ensure that the 3D printed parts loaded in the B9Clean do not soak in isopropyl alcohol longer than the 

specified cleaning cycle duration, the unit will automatically drain the inner container of isopropyl alcohol 
in the following situations. 

 

A cleaning cycle completes 

 

The Start/Stop button is pressed during a cleaning cycle 

 

The B9Clean loses power 

8.2 Isopropyl Alcohol Containment 

When a cleaning cycle is not in progress, all isopropyl alcohol loaded in the 

B9Clean

 is stored in the outer 

container. The inner container creates a seal when placed inside the outer container, isolating the 

isopropyl alcohol from outside interference or contamination. 

 

DO NOT USE Acetone in the B9Clean. Acetone will rapidly destroy acrylic material of containers and 

pump. Warranty is void with even single use of Acetone. 

 

    

FLAMMABLE 

Though the B9Clean’s design reduces risk by separating the isopropyl alcohol in the outer container, 

isopropyl alcohol is still highly flammable in both liquid and vapor states. 

Read the safety information in Section 

2.5

 before handling isopropyl alcohol. 

 

 

Maintenance, Care and Cleaning 

9.1.1  Unit Cleaning 

The components of the unit that come into contact with isopropyl alcohol can be cleaned with water to 

remove uncured resin residue. 

 

  

NOTE 

Ensure that all water completely dries before refilling container and operating the B9Clean. 

Summary of Contents for B9Clean

Page 1: ...USER MANUAL B9Clean...

Page 2: ...nd or registered trademarks of the respective owners The publisher and the author make no claim to these trademarks While every precaution has been taken in the preparation of this document the publis...

Page 3: ...etup 12 7 Operation 13 7 3 Positioning the inner container drain plug 15 7 4 Placing the parts in the inner container 15 7 5 Configuring the cleaning cycle settings 16 7 6 Overview of starting stoppin...

Page 4: ...Technical Specifications 20 10 2 Operating conditions 20 10 3 Information on Manufacturer and Electrical Specification Product Label 21 11 Troubleshooting Guide 21 12 Service 24 13 Quick Reference 24...

Page 5: ...pply to Type of machine Description B9Clean Enclosed isopropyl alcohol agitator for cleansing resin based 3D printed parts of excess uncured resin The B9Clean is an easily operated laboratory grade 3D...

Page 6: ...tage Failure to comply with safety guidelines and procedures can result in electrical shock that may lead to injury or death FLAMMABLE This symbol warns of the dangers of flammable compounds Failure t...

Page 7: ...cumented in this book 2 5 Safety Information Safety concerning the protection of persons the environment and the material to be processed mainly depends on the behavior of the persons operating the un...

Page 8: ...f the required tests maintenance and repair work have been performed by B9Creations LLC or trained and authorized service staff NOTE This equipment has been tested and found to comply with the limits...

Page 9: ...Proper Operation CAUTION The unit is suitable to be set up and operated in clean laboratory environments The unit has been designed for continuous operation Only 3D printed parts made of cured resin...

Page 10: ...on upon delivery of the unit If items are missing or damaged contact your supplier 4 1 Scope of Delivery Build Table included for B9 Core Series owners only A B9Clean Unit B Quick Start Guide C Access...

Page 11: ...f this User Manual NOTE If requesting technical assistance always take note concerning the model number and serial number of the unit 5 2 Control Interface Base Front 1 Start Stop button 2 Cleaning du...

Page 12: ...unter liquid or fluid leaks The unit shall be installed in a low dust environment When not in use the containers shall be placed properly in the base and the lid shall be secured The room temperature...

Page 13: ...onnect the unit to any type of emergency backup generator that is not connected to mains power NOTE If additional hardware is installed it could cause malfunctions to the system Do not install any oth...

Page 14: ...age the B9Clean s electronics or surrounding materials FLAMMABLE Isopropyl alcohol is highly flammable in both liquid and vapor states Read the safety information in Section 2 5 before handling isopro...

Page 15: ...s can be cleaned while still attached to the Build Table or while resting in the part tray If any parts to be cleaned are still attached to the Build Table ensure that the hanging arm is secured to th...

Page 16: ...cycle Before starting the cleaning cycle ensure the following conditions are met The outer container inner container inner container plug hanging arm Build Table and lid are all secured in their prope...

Page 17: ...ints may require more than one wash Do not continuously wash a part for more than 10 minutes as continuous and prolonged submersion in isopropyl can damage the print Recommended Clean Times minutes Re...

Page 18: ...he 3D printed parts loaded in the B9Clean do not soak in isopropyl alcohol longer than the specified cleaning cycle duration the unit will automatically drain the inner container of isopropyl alcohol...

Page 19: ...esin used and part geometry It is solely at the discretion of the operator to determine when the isopropyl alcohol is to be changed 9 2 2 Disposal Isopropyl alcohol is classified as a hazardous waste...

Page 20: ...s plugs included AU EU UK US Required table area 300 mm x 300 mm Package size W x H x D 300 x 365 x 570 mm 11 8 x 14 4 x 22 4 Package weight 5 kg 11 lbs Agitation method Magnetic stirrer Cleaning solv...

Page 21: ...in the table Error description Possible Causes Remedy 1 The indicator lights on the control interface are not lit The power adapter is not plugged into the back of the B9Clean base Plug the power ada...

Page 22: ...cleaning cycle the isopropyl alcohol in the inner container is not being agitated The magnetic stirring bar is not placed in the bottom of the inner container Press the Start Stop button to stop the...

Page 23: ...eaning cycle duration or spin speed settings are too low Increase the duration and spin speed settings to find the optimal values for a particular 3D printed part The 3D printed parts being cleaned ha...

Page 24: ...n and spin speed of a cleaning cycle can be adjusted while the cleaning cycle is in Part height less than 70 millimeters mm Outer container filled to 1 3 liters Inner container with drain plug in top...

Page 25: ...propyl alcohol should be replaced with a fresh batch if the current batch appears dirty or is not cleaning parts effectively 15 Document History Edition Date Comments released 031319 Updates by EH A 0...

Reviews: