Figure 1: Plumbing Connections
Table 3: Plumbing Connections
Water Inlet (WI)
Gas Inlet (GI)
Water Outlet/Waste (D)
Connection
Position from
Position from
Position from
Floor
Rear of Appliance
LHS/RHS edge
(mm)
(mm)
of Appliance
(mm)
½
” Copper
310 (+/-5)
60 (+/-5)
220 (+/-5)
¾
” male BSP
310 (+/-5)
70 (+/-5)
120 (+/-5)
2
” BSP
410 (+/-5)
780 (+/-5)
110 (+/-5)
Installation Instructions
Regulations
The appliance
must
be installed only by authorised persons and in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building codes, AS 5601
– Gas Installations
and any other health and safety regulations, local authority, gas, electrical any other statutory regulations.
Data Label
The data label is located on the front of the appliance. This appliance is suitable for Natural Gas and LPG.
Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the
appliance being installed and that adequate supply pressure and volume is available
– refer to appliance
data plate for Mj/hr consumption, injector sizes of main burners/pilots, etc.
Ventilation
It is strongly recommended that the appliance is installed under an extraction hood. Ventilation must be in
accordance with AS5601 - Gas Installations. In general, the appliance should have adequate ventilation for
complete combustion of gas, proper flueing and to maintain temperature of immediate surroundings within
safe limits. It is
strongly
recommended that this appliance is installed under an extraction hood.
Combustible Surfaces
Clearances to combustible surfaces must be in accordance with AS/NZS 5601.1 -
Gas Installations
,
clause
5.12.4.5.
Install on a flat/level floor. Where the floor is not fire resistant, a fire resistant material shall be put
under the appliance which shall have a fire resistance rating at least equal to that of 10mm millboard. The
material shall extend at least 50mm beyond the edge of the appliance.