background image

10 

 

IMPORTANT WARNING! 

IN THE EVENT OF FAILURE OF THE WOKSPOUT, WATER FLOW CAN BE CONTROLLED MANUALLY 

BY USING THE SPINDLE LOCATED ON FRONT PANEL (WHERE FITTED). WHERE NO SPINDLE 

FITTED, WATER SHOULD BE SWITCHED OFF FROM THE ISOLATION VALVE (WHICH IS 

RECOMMENDED TO BE FITTED WHEN ISTALLED) AND CONTACT AUTHORISED/ LICENSED 

SERVICE PERSONNEL. 

 

Maintenance and Care 

To  ensure  longevity  and  continued  performance  efficiency  of  you  appliance,  a  good  cleaning  and 
maintenance  program  is  paramount.  In  general  the  use  of  steel  wool  abrasive  cloths/cleaners/powders 

should not

 be used to clean this appliance. 

 

Daily Checks & Service 

 

Look  for  any  foreign  materials  in  burner  area, leaks,  damaged  knobs  and  any  other  signs  that the 
stock  pot  table  is  not  ready  and  safe  for  operation.  Inspect  burner  area  and  ensure  pilots  are  in 
position near the burner, and that the pilot flame when ignited is blue in color and approximately 20-
40mm  in  length.  If  fitted  with  thermocouple  ensure  pilot  flame  is  in  contact  with  it.  Call  the 
manufacturer if you see any problems. Always ensure that area surrounding pilot and thermocouple 
is clear of any fats, oils or foodstuffs. 

 

Clean the exterior surfaces of the stock pot with a clean, damp cloth soaked with mild detergent to 
remove any food stuffs, oils, dust and any other materials. 

 

Ensure  the  primary  water  drain  (located  in  gutter)  is  cleared  of  any  food  stuffs during  operation  of 
the appliance and on completion of use of the appliance. 

 

The spillage trays located under the main body of the appliance should be removed (by pulling out) 
and  any  carbonised  foodstuffs  and  oils  should  be  removed  using  a  clean, damp  cloth  soaked  in  a 
mild detergent. 

 

Fortnightly checks & Service 

Clean Stock Pot Table Burners 

 

TO BE CARRIED OUT IN THE MORNING OR WHEN THE APPLIANCE HAS NOT BEEN IN USE 
FOR A PERIOD OF ONE (1) HOUR 

– ALWAYS USE CAUTION AS BURNER AREA MAY BE HOT. 

 

Yearly Checks & Service 

 

The appliance should be inspected and adjusted periodically by a qualified service person as 
part of any kitchen maintenance program. 

 

B&S  recommends  that  this  appliance  is  inspected  at  least  annually  by  a  authorised  service 
technician as follows: 

o

 

Inspect the table inside-out for excessive build-up of any fats, oils and foodstuffs.

 

o

 

Inspect that the burners and other components (i.e. pilots, thermocouples, etc.) are in good 
condition and functioning properly.

 

o

 

Inspect all gas connections for leaks and ensure all connections are tightened properly.

 

o

 

Ensure burner manifold pressure is in accordance with that specified on the data plate of the 
appliance.

 

o

 

Inspect all gas connections for leaks and ensure all connections are tightened properly.

 

 

In case of difficulties, contact B&S Commecial Kitchens Pty Ltd or their authorised service agent. 

 

 

 

Summary of Contents for UFWSP Series

Page 1: ...54 Fax 61 3 94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves t...

Page 2: ...ation Instructions 6 Regulations 6 Data Label 6 Ventilation 6 Combustible Surfaces 6 Gas Connection 7 Pressure Test Point 7 Water Connection 7 Before Leaving Commissioning 7 Operating Instructions 8 IMPORTANT WARNING 8 IMPORTANT WARNING 8 Lighting Instructions 8 Shutdown Procedure 9 Deck Cooking Water Spray Where Fitted Water Cooled Models 9 Telescopic Laundry Arm Manual Control Water Cooled Model...

Page 3: ...1 Gaining Access to Gas and or Water System 11 Removal of Burner for Service 11 Pilot and Flame Safeguard 11 Adjustments 12 Servicing WokSpout Where Fitted 12 Servicing Knee Valve Where Fitted 12 Gas Type Conversion 12 Table 4 Spare Parts List 13 Table 5 Troubleshooting 14 ...

Page 4: ...allation of the appliance please contact your B S dealer immediately In most instances a phone call could answer your question Manufactured By Certificate Holder Model Number s Approval Number Gas Types B S Commercial Kitchen s Pty Ltd 57 Plateau Road Reservoir Victoria 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com How to read model numbers UFW W D SP 1 2 3 CB LS ...

Page 5: ...IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS PARTS THAT MAY HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B S WARRANTY AND M...

Page 6: ...gas supply is correct for the appliance being installed and that adequate supply pressure and volume is available refer to appliance data plate for Mj hr consumption injector sizes of main burners pilots etc Ventilation It is strongly recommended that the appliance is installed under an extraction hood Ventilation must be in accordance with AS5601 Gas Installations In general the appliance should ...

Page 7: ...2 60 kPa LPG with the burners operating at maximum Water Connection The water connection is 15mm copper and is situated at the rear of the appliance below the main body frame The number of water inlets varies to client s particular needs Water isolation valves are fitted to all water inlets Ensure water is flushed through before final connection Water waste outlet is located on the left hand side ...

Page 8: ...gas please note that as some gas types are heavier than air we recommended the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phone in your building Call local gas supplier immediately and follow their instructions IMPORTANT WARNING ALWAYS ENSURE DECK COOLING IS ACTIVATED WHILST MAIN BURNER I...

Page 9: ... FROM TELESCOPIC LAUNDRY ARM WHILST POSITIONED OVER THE STOCK POT SUPPORT RING WITH NO POT PAN POSITIONED ON IT ALWAYS MOVE TELESCOPIC LAUNDRY ARM PARALLEL TO THE SPLASHBACK OG THE APPLIANCE WHENNOT IN USE DIRECT FLAME CONTACT WITH LAUNDRY ARM MAY DAMAGE OPERATION OF LAUNDRY ARM SPOUT Waterset Automatic Laundry Arm WokSpout Where Fitted The WokSpout automatically shuts off the water flow when it I...

Page 10: ...ils dust and any other materials Ensure the primary water drain located in gutter is cleared of any food stuffs during operation of the appliance and on completion of use of the appliance The spillage trays located under the main body of the appliance should be removed by pulling out and any carbonised foodstuffs and oils should be removed using a clean damp cloth soaked in a mild detergent Fortni...

Page 11: ...e b Gently remove dome handle by gently pulling forward c Unscrew flange by turning anti clockwise d Unscrew water spindle by turning anti clockwise ensure spindle washer is removed 6 Remove screws located on bottom corners of front panel Ensure any screws located on the inside of the gutter panel are also removed 7 Gently pull front panel outwards from the bottom and lift front panel upwards 8 RE...

Page 12: ... service be carried out every two years Please contact manufacturer for service kit Servicing Knee Valve Where Fitted The knee valve incorporates a cartridge design for ease of service 1 Follow procedure described under GAINING ACCESS TO GAS AND OR WATER SYSTEM 2 To gain access to knee valve cartridge undo knee valve where the deflector meets the cartridge area 3 REASSAMBLE IN REVERSE ORDER Gas Ty...

Page 13: ...rmocouple Front row burner boiling top section flame failure device 665NG Oara Regulator Natural Gas 665LP Oara Regulator Propane Gas 020 Telescopic Laundry Arm 503 Pilot Shield 504A 12 Flexi Tube From Flame Failure Device to Pilot Gas Cock 504B 18 Flexi Tube From Pilot Gas Cock to Light Burner W001 Knee Valve W004 Cartridge W002 Waterset Laundry Arm W003 Lever Handle W005 Retaining Disk and Handl...

Page 14: ...ing Faulty thermocouple Faulty flame failure control valve Contact manufacturer Contact manufacturer Telescopic laundry arm constantly running on water deck cooled stock pot table Warn tap washer Change washers in tap assembly Contact manufacturer or authorised service agent Wokspout constantly running water when in OFF position Faulty O ring in Wokspout Changing of O ring as per service kit and i...

Reviews: