background image

 

Chimney Burners 

– Pilot Light Chimney Burner

 

A.  

Ensure pilot light head is located no further than 45mm from the injector located opposite the 

burner inlet. 

 

 
In the event the appliance fails to operate correctly, check the following; 

1.   Data plate to ensure correct gas type and pressure (adjust if necessary) 
2.   Adjust aeration by adjusting air shutter located at the front of the venture of the main burner. 
3.   Injector sizes 

– check against data plate and installation manual 

4.   View pilot size and adjust if required. 

 

In case appliance fails to operate correctly after all checks have been carried out, pleased contact; 

B&S Commercial Kitchens Pty Ltd

 

57 Plateau Road 
Reservoir   VIC   3073 
Tel.: + 61 3 9469 4754     Fax.: + 61 3 9469 4504     E-mail: [email protected] 

 

Operating Instructions 

 

WARNING

 

 

DO NOT

 spray aerosols in the vicinity of this appliance while it is in operation. 

 

DO NOT

 store or use flammable liquids or items in the vicinity of this appliance. 

 

Prior  to  lighting,  smell  area  surrounding  the  appliance  for  gas  (please  note  that  as 
some  gas  types  are  heavier  than  air,  we  recommended  the  operator  to  also  smell 
the floor around the appliance). 

 

In  the  event  you  smell  gas: 

DO  NOT

  light  any  appliance. 

DO  NOT

  touch/  operate 

any  electrical switch or phone  in  your building. Call  local  gas supplier 

immediately

 

and follow their instructions. 

 

IMPORTANT WARNING! 

ALWAYS 

ENSURE DECK COOLING IS ACTIVATED WHILST MAIN BURNER IS OPERATING (WHERE 

FITTED). WHEN MAIN BURNERS NOT IN USE ALWAYS ENSURE WATER DECK COOLING IS TURNED 

OFF TO MINIMISE WATER CONSUMPTION/WASTAGE 

– REFER OPERATION INSTRUCTIONS. 

 

IMPORTANT WARNING! 

ENSURE NO OR MINIMAL AMOUNTS OF OIL AND FOODSTUFFS FALL INTO THE BURNER AREA 

WHILST COOKING. FAILURE TO DO SO MAY AFFECT THE EFFICIENT AND SAFE OPERATION ON 

THE APPLIANCE AND 

MAY VOID WARRANTY 

 

Lighting Instructions 

1. 

Turn main gas valve to ‘OFF’. 

2.  Turn pilot valve anti-

clockwise to ‘ON’ position. 

3.  Depress blue button on flame failure control and manually ignite light pilot.  
4.  When  pilot  is  alight,  keep  holding  down  the  blue  flame  failure  but ton  for  approximately  15 

seconds. 

5.  Observe  the  pilot  flame  is  established. 

If  pilot  flame  goes  out  wait  five  minutes  and  repeat 

steps 1 to 4

6. 

Turn main gas valve to ‘HIGH’ position. 

Summary of Contents for UFWSP Series

Page 1: ...54 Fax 61 3 94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves t...

Page 2: ...ation Instructions 6 Regulations 6 Data Label 6 Ventilation 6 Combustible Surfaces 6 Gas Connection 7 Pressure Test Point 7 Water Connection 7 Before Leaving Commissioning 7 Operating Instructions 8 IMPORTANT WARNING 8 IMPORTANT WARNING 8 Lighting Instructions 8 Shutdown Procedure 9 Deck Cooking Water Spray Where Fitted Water Cooled Models 9 Telescopic Laundry Arm Manual Control Water Cooled Model...

Page 3: ...1 Gaining Access to Gas and or Water System 11 Removal of Burner for Service 11 Pilot and Flame Safeguard 11 Adjustments 12 Servicing WokSpout Where Fitted 12 Servicing Knee Valve Where Fitted 12 Gas Type Conversion 12 Table 4 Spare Parts List 13 Table 5 Troubleshooting 14 ...

Page 4: ...allation of the appliance please contact your B S dealer immediately In most instances a phone call could answer your question Manufactured By Certificate Holder Model Number s Approval Number Gas Types B S Commercial Kitchen s Pty Ltd 57 Plateau Road Reservoir Victoria 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com How to read model numbers UFW W D SP 1 2 3 CB LS ...

Page 5: ...IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS PARTS THAT MAY HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B S WARRANTY AND M...

Page 6: ...gas supply is correct for the appliance being installed and that adequate supply pressure and volume is available refer to appliance data plate for Mj hr consumption injector sizes of main burners pilots etc Ventilation It is strongly recommended that the appliance is installed under an extraction hood Ventilation must be in accordance with AS5601 Gas Installations In general the appliance should ...

Page 7: ...2 60 kPa LPG with the burners operating at maximum Water Connection The water connection is 15mm copper and is situated at the rear of the appliance below the main body frame The number of water inlets varies to client s particular needs Water isolation valves are fitted to all water inlets Ensure water is flushed through before final connection Water waste outlet is located on the left hand side ...

Page 8: ...gas please note that as some gas types are heavier than air we recommended the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phone in your building Call local gas supplier immediately and follow their instructions IMPORTANT WARNING ALWAYS ENSURE DECK COOLING IS ACTIVATED WHILST MAIN BURNER I...

Page 9: ... FROM TELESCOPIC LAUNDRY ARM WHILST POSITIONED OVER THE STOCK POT SUPPORT RING WITH NO POT PAN POSITIONED ON IT ALWAYS MOVE TELESCOPIC LAUNDRY ARM PARALLEL TO THE SPLASHBACK OG THE APPLIANCE WHENNOT IN USE DIRECT FLAME CONTACT WITH LAUNDRY ARM MAY DAMAGE OPERATION OF LAUNDRY ARM SPOUT Waterset Automatic Laundry Arm WokSpout Where Fitted The WokSpout automatically shuts off the water flow when it I...

Page 10: ...ils dust and any other materials Ensure the primary water drain located in gutter is cleared of any food stuffs during operation of the appliance and on completion of use of the appliance The spillage trays located under the main body of the appliance should be removed by pulling out and any carbonised foodstuffs and oils should be removed using a clean damp cloth soaked in a mild detergent Fortni...

Page 11: ...e b Gently remove dome handle by gently pulling forward c Unscrew flange by turning anti clockwise d Unscrew water spindle by turning anti clockwise ensure spindle washer is removed 6 Remove screws located on bottom corners of front panel Ensure any screws located on the inside of the gutter panel are also removed 7 Gently pull front panel outwards from the bottom and lift front panel upwards 8 RE...

Page 12: ... service be carried out every two years Please contact manufacturer for service kit Servicing Knee Valve Where Fitted The knee valve incorporates a cartridge design for ease of service 1 Follow procedure described under GAINING ACCESS TO GAS AND OR WATER SYSTEM 2 To gain access to knee valve cartridge undo knee valve where the deflector meets the cartridge area 3 REASSAMBLE IN REVERSE ORDER Gas Ty...

Page 13: ...rmocouple Front row burner boiling top section flame failure device 665NG Oara Regulator Natural Gas 665LP Oara Regulator Propane Gas 020 Telescopic Laundry Arm 503 Pilot Shield 504A 12 Flexi Tube From Flame Failure Device to Pilot Gas Cock 504B 18 Flexi Tube From Pilot Gas Cock to Light Burner W001 Knee Valve W004 Cartridge W002 Waterset Laundry Arm W003 Lever Handle W005 Retaining Disk and Handl...

Page 14: ...ing Faulty thermocouple Faulty flame failure control valve Contact manufacturer Contact manufacturer Telescopic laundry arm constantly running on water deck cooled stock pot table Warn tap washer Change washers in tap assembly Contact manufacturer or authorised service agent Wokspout constantly running water when in OFF position Faulty O ring in Wokspout Changing of O ring as per service kit and i...