12
c. Remove injector from pilot and clean (if required).
d. Reassemble in reverse order.
3.
REASSEMBLE IN REVERSE ORDER.
Adjustments
Pilot
1.
Remove front panel as described under GAINING ACCESS TO GAS CONTROL.
2.
To increase gas pressure to pilot, turn adjustment screw located at the top right hand side of the
flame failure devise anti-clockwise.
3.
To decrease gas pressure to pilot, turn adjustment screw located at the top right hand side of the
flame failure devise clockwise.
4.
REASSEMBLE IN REVERSE ORDER ENSURING POSITION OF PILOT IS AS FOLLOWS;
Ensure pilot light head is light head is located no further than 45mm from the injector located
opposite the burner inlet.
Servicing WokSpout
– Where Fitted
The WokSpout TM has a few wearing parts and these comprise a single flow control O-ring in the tap body
and two sealing O-rings on the swivel spout. Whilst it is expected that servicing would only be required at
approximately 200,000 cycles, it recommended that a preventative service be carried out every two years.
Please contact manufacturer for service kit.
Servicing Knee Valve
– Where Fitted
The knee valve incorporates a cartridge design for ease of service.
1.
Follow procedure described under GAINING ACCESS TO GAS AND/OR WATER SYSTEM
2.
To gain access to knee valve cartridge undo knee valve where the deflector meets the cartridge
area.
3.
REASSAMBLE IN REVERSE ORDER.
Gas Type Conversion
The following parts componentry require changing the appliance from NG to LPG (vice-versa);
1.
Regulator.
2.
Burner.
3.
Pilot.
In case of any failure in the functioning of the knee valve, unscrew the head assembly and clean the
mechanism under running water. Only use liquid cleaning products. All cleaning products containing
dry powder or powder in suspension are not to be used!
A specific devise is integrated in the cartridge unit to adjust the flow rate. To adjust the flow rate;
1.
Undo head assembly
2.
Pull off flow adjustor
3.
On the exposed end of the housing there are 4 cut-outs for alternative flow rates.
4.
Select one for increased/reduced flow.
5.
Replace flow adjustor with window over selected cut-out.
6.
Screw head assembly into the tap body and tighten fully.