Appliance 

Name: 

TF Series Turbo Fryer and RF series Rapid fryer 

Unit is also marketed under the brand name B+S Black ,Verro and K 
plus 

Manufactured By: 
Certificate Holder: 

B&S Commercial Kitchens Pty Ltd 
57 Plateau Road 

Reservoir   Victoria   3073 
Tel; + 61 3 9469 4754     Fax: +61 3 9469 4504 

E-mail; [email protected] 

Model 

Number/s: 

Supplied in various configurations. 

 

How to read model numbers;  

(V)(K)TF 

  45/60 

 1/2/3/4- P-s 



     



 



TF 

 Turbo Fryer

 

   

No of rectangular baskets per pan 

            40 - 

400mm per appliance width (2 baskets per pan)  

 

            45

 

 450mm per appliance width (2 baskets per pan) 

            60

 

 600mm per appliance width (3 baskets per pan) 

Number of fryer pans per unit 

1

 

 one pan 

2

 

 two pan 

3

 

 three pan 

4

 

 four pan 

    



P- 

Plinth mounted (VTF-601 and VTF-451s only) 



 s- 

split pan (VTF-451s) 

K indicates K plus model 
V at the beginning indicates Verro model 
RF indicates Rapid fryer 

RF 400 mean Rapid fryer 400mm wide 

E.G.    

TF-453 

Is  a  fryer  with  three  separate  pans  each  holding  up  to  two  rectangular 
baskets per pan

 

Approval  

GMK 10683 

 

We are confident that you will be delighted with your B&S Turbo Fryer, and that it will become the backbone of your 
kitchen.  To ensure you receive the utmost benefit from your new B&S appliance, there are two important things you 
can do. 

1.

 

Ensure you read this booklet carefully and carefully follow the instructions given. Ensure that this booklet is 
kept in a safe and prominent location for future reference. 
 

2.

 

Should you be unsure of any aspect of the operation/performance, servicing and installation of the appliance, 
please contact your B&S dealer immediately.  In most instances a phone call could answer your questio 

Summary of Contents for TF Series

Page 1: ...073 AUSTRALIA Tel 61 3 9469 4754 Fax 61 3 94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copy...

Page 2: ...Plumbing Connections Verro TF 451 Black TF 451 7 TABLE 4 Plumbing Connections 8 FIGURE 3 Plumbing Connections Verro TF 451s 8 TABLE 5 Plumbing Connections 8 TABLE 5 Plumbing Connections 9 Installation...

Page 3: ...nance and Care 15 Servicing Instructions 16 Abnormal Operation 16 Panel Removing 17 Controls 17 Thermostat 17 Pilot Assembly 17 Piezo Assembly 17 Burners 18 Gas Valve 18 TABLE 4 Troubleshooting 18 STA...

Page 4: ...pan 4 four pan P Plinthmounted VTF 601andVTF 451sonly s splitpan VTF 451s KindicatesKplusmodel VatthebeginningindicatesVerromodel RF indicates Rapid fryer RF 400 mean Rapid fryer 400mm wide E G TF 453...

Page 5: ...ROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION ENSURE ANY TRANSIENT PROTECTION IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS...

Page 6: ...requirements TABLE 2 STANDARD MODEL GENERAL INFORMATION Weight kg Overall Height mm Overall Depth mm Overall Width mm RF 400 100 1130 800 400 TF 451 100 1 130 800 450 TF 452 200 1 130 800 900 TF 453 3...

Page 7: ...BLE 3 PLUMBING CONNECTIONS Connection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Gas Inlet GI male BSP 230 5 575 5 57 5 RHS Oil drain valve 1...

Page 8: ...NNECTIONS Connection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Gas Inlet GI male BSP 235 5 580 5 60 5 RHS Oil drain valve OO Oil drain valve...

Page 9: ...CTIONS Connection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Gas Inlet GI male BSP 270 5 156 5 50 5 RHS Oil drain valve D1 Oil drain valve D2...

Page 10: ...The hood shall be located so as to effectively ventilate the fryer The exhaust duct system shall be adequately sized and shall not get connected to any other ventilating or exhaust system As suitable...

Page 11: ...relating to health protection 3 Care should be taken where a combustible surface is covered by a non combustible material for example covering a combustible surface with stainless steel will not preve...

Page 12: ...sition and allow 5 minutes for any gas in combustion chamber to escape propane gas being heavier than air may require forced ventilation Note If knob is in ON flame position turn clockwise to PILOT sp...

Page 13: ...o smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phone in your building Call the local gas supplier immediatel...

Page 14: ...es B S Commercial Kitchens 14 FIGURE 4 FRYER RANGE KNOWING YOUR APPLIANCE Splashback Hob Oil drain access behind the door Fryer baskets Thermostat knob Splashback Hob Oil drain access behind the door...

Page 15: ...iezo while depressing the gas valve knob 5 Keep knob fully depressed for one full minute 6 Release gas valve knob Pilot flame should continue to burn Observe pilot is established If pilot goes out whe...

Page 16: ...ized cooking oil will gradually form on the inside of the fryer pan We strongly advise this deposit is removed to ensure your fryer is operating efficiently YEARLY CHECKS SERVICE The appliance should...

Page 17: ...thermostat reverse the above procedures PILOT ASSEMBLY 1 Undo the two screws holding the pilot bracket onto the burner mount bar 2 Gently pull the pilot assembly bracket down and outwards 3 To change...

Page 18: ...unting screws on the gas valve support bracket h Gently remove main gas valve i Reassemble in reverse order TABLE 4 TROUBLESHOOTING FAULT POSSIBLE CAUSE CHECKS Pilot light not igniting Blockage of pil...

Page 19: ...f the appliance has been installed in accordance with local regulations by a duly authorised person and the B S installation instructions provided with the appliance If in doubt please contact B S or...

Page 20: ...not covered by warranty Breakage of pilot knobs knee valve handles and knee wands are not covered under warranty Thermocouples piezo leads and ignitors are only covered by twelve 12 months parts and l...

Reviews: