Warning!

 

 

 

ENSURE WATER TANK DRAIN VALVE IS FULLY CLOSED AND WATER TANK DRAIN VALVE IS 

 

ACCESSED BY TURNING GATE VALVE HANDLE CLOCKWISE (LOCATED UNDERNEATH THE RIGHT-HAND 

SIDE OF THE APPLIANCE) BELOW MAIN WATER TANK. 

 

 

 

 

Shutdown Procedure  

1. 

Turn main gas valve to ‘OFF”.  

2. 

Turn pilot control valve clockwise to turn off.  

3. 

Observe pilot flame is extinguished.  

 

Warning!

 

 

 

WHEN OPENING DOORS FROM STEAMING AREAS, ALWAYS ENSURE MAIN STEAM CONTROL IS 

 

PULLED TO THE 'OFF' POSITION. THIS IS TO ENSURE THAT THE FLOW OF STEAM IS MINIMISED WHILST 

THE DOORS ARE OPENED. FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY. 

 

  

Maintenance Schedule  
Daily Checks & Service

 

 

• 

Look for any foreign materials in burner area, leaks, damaged knobs  and any other signs that the steamer is 
not ready and safe for operation.  

• 

Inspect burner area and ensure pilot is in position near the burner, and that the pilot flame when ignited is blue 
in  color  and  approximately  10-20mm  in  length.  Ensure  pilot  flame  is  in  contact  with  thermocouple.  Call  the 
manufacturer if you see any problems. Always ensure that area surrounding pilot and thermocouple is clear of 
any fats, oils or foodstuffs.  

• 

Clean the exterior surfaces of the steamer with a clean, damp cloth soaked with mild detergent to remove any 
food stuffs, oils, dust and any other materials.  

• 

Ensure the primary water drain and steam outlet are cleared of any food stuffs.  

  
  

Weekly Checks & Service  

• 

Ensure  water  tank  is  emptied  on  a  weekly  basis.  Water  tank  drain  valve  is  accessed  from  underneath  the 
appliance and turning  gate valve handle anti-clockwise (located on the right hand side below main water tank). 
Turn drain valve clockwise to stop.  

• 

Inspect burner area and ensure pilot is in position near the burner, and that the pilot flame when ignited is blue 
in  color  and  approximately  10-20mm  in  length.  Ensure  pilot  flame  is  in  contact  with  thermocouple.  Call  the 
manufacturer if you see any problems. Always ensure that area surrounding pilot and thermocouple is clear of 
any fats, oils or foodstuffs.  

• 

 

  

Yearly Periodic Checks & Service  

• 

The appliance should be inspected and adjusted periodically by a qualified service person as part of 
any kitchen maintenance program. B&S recommends that this appliance is inspected at least annually 
by an authorized service technician as follows: 

 

• 

Inspect the table inside-out for excessive build-up of any fats, oils and foodstuffs.  

• 

Inspect  that  the  burners  and  other  components  (i.e.  pilots,  thermocouples,  etc.)  are  in  good  condition  and 
functioning properly.  

• 

Inspect all gas connections for leaks and ensure all connections are tightened properly.  

• 

Ensure burner pressure is in accordance with that specified on the data plate of the appliance.

 

 

 

 

 

In case appliance fails to operate correctly after all checks have been carried out, please contact;  

 

Summary of Contents for DSK Series

Page 1: ... Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves the right to change t...

Page 2: ...structions 6 Regulations 6 Data Label 7 Ventilation 7 Combustible Surfaces 7 Gas Connection 7 Water and Drainage Connection 7 Before Leaving 8 Operating Instructions 8 Shutdown Procedure 9 Maintenance Schedule 9 SERVICING INSTRUCTIONS 10 Abnormal Operation 10 Gaining Access to Gas System 10 Removal of Burner for Service 10 Pilot and Flame Safeguard 10 Over Temperature Cut Out Device on D3 Unit 10 ...

Page 3: ...3 STANDARD WARRANTY CONDITIONS 13 ...

Page 4: ...ormance servicing and installation of the appliance please contact your B S dealer immediately In most instances a phone call could answer your question Table 1 Nominal Terminal Input Rates Injector Size Orifices Gas Type Injector Size Main Burner Pilot mm Gas Test Point Pressure kPa MJ h Rating per Burner Total Nominal Gas Consumption DS 2 3 LPG 2 00 1 00 2 60 150 150 MJ h DS 2 3 NG 3 10 1 55 1 0...

Page 5: ...nnection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Water Inlet WI nonreturn valve 120 5 620 5 125 5 LHS Gas Inlet GI male BSP 145 5 670 5 210 5 LHS Tank drain D1 1 male BSP 110 5 390 5 245 5 RHS Waste D2 1 BSP 120 5 400 5 85 5 LHS ...

Page 6: ...ce when gas is available at the time of installation or b Makes gas available to the appliance if gas was not available at the time of installation As per AS NZS5601 1 clause 6 11 3 the commissioning of this appliance shall take full account of special design features the manufacturer s instructions and the appliance safety requirements As per AS NZS5601 1 clause 6 11 4 the commission of this appl...

Page 7: ...rfaces Clearances to combustible surfaces must be in accordance with AS NZS 5601 1 Gas Installations clause 5 12 4 5 Install on a flat solid fire proof base Leave at least 200mm between the appliance and the side and rear walls The Steamer shall be installed so that a clear space of 200mm is maintained between the sides of the steamer and any other appliance No combustible material shall be locate...

Page 8: ...n the control panel door is opened 5 Make sure pilot burns well and then switch on the burners by rotating the relevant ball valve anit clockwise to the ON position as indicated The left Ball Valve operates the left hand side burner whilst the right Ball Valve operates the two right hand side burners 6 If the burner extinguishes wait at least 5 minutes to relight and repeat from step2 to step 5 7 ...

Page 9: ...rials Ensure the primary water drain and steam outlet are cleared of any food stuffs Weekly Checks Service Ensure water tank is emptied on a weekly basis Water tank drain valve is accessed from underneath the appliance and turning gate valve handle anti clockwise located on the right hand side below main water tank Turn drain valve clockwise to stop Inspect burner area and ensure pilot is in posit...

Page 10: ...assemble the panel in the reverse order Removal of Burner for Service Follow procedure described under GAINING ACCESS TO GAS SYSTEM Remove burner by undoing bolt assembly located on the burner support bracket Gently lift burner upwards slightly and pull burner outwards REASSEMBLE IN REVERSE ORDER Pilot and Flame Safeguard Access to the D3 unit pilot assembly is gained by removing the front control...

Page 11: ... Fax 61 3 9469 4504 E mail info bscommercialkitchens com Adjustments Pilot 1 Remove front panel as described under GAINING ACCESS TO GAS CONTROLS 2 To increase gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devise anti clockwise 3 To decrease gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devi...

Page 12: ...roubleshooting In case of difficulties or for spare parts please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com ...

Page 13: ...r or not a fault is caused by faulty workmanship or material or that any part is defective 6 This warranty does not apply to any loss suffered through or resulting from the non operation or the ineffective operation of the cooking appliance or any part of the cooking appliance 7 This warranty does not extend to goods and components thereof manufactured either entirely or substantially of glass or ...

Reviews: