B.PROTHERM Stainless-Steel, Cooled
– 24 –
Food varies greatly in temperature
Increased amount of
condensation water in
condensation-water catch tray
Temperature display of
temperature regulator flashes –
temperature overshoot
Temperature regulator is in an
irregular condition.
Pull the power plug and reinsert it
after approx. 10 seconds.
If this does not solve the problem and
the causes we have already men-
tioned can be ruled out, notify an
authorized repairs facility.
Refrigeration unit failed or dam-
aged.
Notify a facility authorized to carry out
repairs.
The unit electronic system is
defective.
Notify a facility authorized to carry out
repairs.
Cause
Action
Cause
Action
Air baffle not mounted on inside
of door.
Mount air baffle.
Subsection "Unhooking air baffle"
on Page 28.
Convection revision panel not
mounted.
Mount convection revision panel.
Subsection "Cleaning convection
revision panel" on Page 29.
Cause
Action
Door seal is missing or dam-
aged.
Notify a facility authorized to carry out
repairs.
Cause
Action
High ambient temperature.
Move the unit to a cooler location.
– or –
Have a refrigeration technician
change the refrigeration parameters
of the temperature regulator.
The evaporator is covered with
ice.
Defrost the unit.
Subsection "Defrosting the unit
manually" on Page 14.
Refrigeration unit failed or dam-
aged.
Notify a facility authorized to carry out
repairs.