HYDROCLIMA 2 - User Manual
Button
Alarms
The timing of button pressure corresponds to the following events:
In the status field we have an error/event report. Possible errors / events are listed in the table.
→ Non-configured heat cost allocator (factory settings); Pressing the button for the first time prepares the device to
receive the configuration data. After a successful configuration the “CONF” information appears in the display.
→ Previously configured heat cost allocator (normal operation mode):
¬ Pushing of the button not longer than 2 seconds - initiation of the display basic data described in the previous
chapter
¬ Pushing of the button longer than 3 seconds - initiation of the display extended data described in the previous
chapter
¬ Pushing of the button longer than 5 seconds - the allocator activate rf transmitting mode that allow the
communication with software in two modes:
~ Change of the operation configuration. Successful configuration is confirmed by “CONF” information
displayed in the display for 10 s. In case the configuration is not successful, it is necessary to release the
button and push it again
~ Sending of the following extended data:
· a pack including history of units memorized at the end of 24 previously months
· a pack including a history of average temperatures for recent 24 months
· a pack comprising all data stored in the memory of the heat cost allocator
Event/Error
Description
C 15
Power failure has been recorded. Power supply has been temporarily lost, all data has been restored from non-volatile memory.
C 13
A quartz oscillator malfunction event has been recorded. Flag deleted automatically after date and time update.
C 11
The overflow of the heat consumption indication parameter [C] was recorded. Closing the billing period does not clear this flag,
therefore the overflow event may also relate to the past period.
C 10
Reduced temperature was recorded for a longer period (radiator temperature parameter TK). The value of the TK radiator
temperature parameter below 16 ° C was registered for a period longer than 24h.
C 9
Exceeding the range of permissible temperature values (radiator temperature parameter TK).
Permitted temperature range is: <5 ° C ... 95 ° C>
B 8
An open case event was recorded, the date of first occurrence is recorded. Clearing this flag also resets the date of occurrence. The
flag can be cleared automatically in the event of the first seal application after the configuration process.
A 1
State of verification of the opening sensor and button. The flag is cleared automatically after closing the cover and pressing the
button.
A 0
Default configuration parameter values. Device not configured or data from non-volatile memory lost; flag cleared automatically
after the configuration process.