Configure Menu
In Setting and Measure page, press Configure key to open the Configuration page. The
Configuration page includes three softkey options:
1.
Config 1 (default)
2.
Config 2
3.
Limits
Each of these pages will be explained below with more detail.
Figure 26 - Default Configuration 1 Menu
8.1
Config 1
Configurations listed below can be edited in this Configuration 1 page.
Configurations
Range
Description
Range
150 V, 300 V
Select the range of AC output voltage
Couple
AC, DC or
AC+DC
Select the coupling of output voltage
Power On State
OFF, LAST, USER OFF: When power on, the output is OFF.
LAST: When power on, the settings will
restore to the pre-shutdown state.
USER: When power on, users need to set the
output value and status. (Volts(rms),
Volts(DC), Freq, Sync Source )
Inrush Current
Measurement
Time (ms)
0 to 10000 ms
Set the time interval to measure Inrush
current
Inrush Current
Delay Time (ms)
0 to 10000 ms
Set the delay time to measure Inrush current
Table 11 - Config 1 Configurations
Summary of Contents for 9830B Series
Page 1: ...1 9830B Series USER MANUAL Model 9832B 9833B High Power Programmable AC Power Sources ...
Page 10: ...ix 2 Notations TEXT Denotes a softkey TEXT Denotes a front panel key ...
Page 28: ...15 6 Menu Tree ...
Page 86: ...73 THD 11 Harmonic 3 weight 21 3 THD 12 Harmonic 3 weight 24 5 ...
Page 88: ...75 THD 15 Harmonic 5 7 weight 2 45 3 95 THD 16 Harmonic 3 5 7 9 weight 11 4 05 2 1 3 ...
Page 89: ...76 THD 17 Harmonic 3 5 9 weight 7 17 3 42 0 8 THD 18 Harmonic 3 5 9 weight 8 11 3 48 1 ...
Page 95: ...82 THD 29 Harmonic 3 5 7 9 11 13 15 weight 33 3 20 13 8 10 8 8 5 7 2 5 5 ...