REVISION DATE
7-29-09
REFERENCE NUMBER
INS-1557
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM4RM SURFACE MOUNT
Surface Mount installation (low voltage)
4.
Attach the UPM housing at mounting brackets
with ¼” fasteners (by others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
5.
Connect 3/4” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance for
water if not properly sealed. Seal connector
threads and conduit with a suitable sealant
(Teflon tape, adhesive, etc.). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
6.
Pull branch circuit wiring necessary for
installation (By Others.)
7.
Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
Ground
Hot
Neutral
XFMR
FUSE
FUSE
LAMP COM 2
LAMP COM 1
LAMP 2
LAMP 1
LINE V
COM
9.
Pull secondary leads into UPM housing and
connect to one of the two 15 Amp, 12VAC
circuits on the transformers terminal block.
NOTE: Each circuit is rated for 150 watts
9.
Make sure UPM housing gasket is free of any dirt
or debris. Attach the faceplate by tightening the
(6) #10-24 captive screws evenly to 30 in/lbs
using a 1/8” allen wrench.
8.
Use wire connectors (By Others) to connect
branch circuit wires to primary leads on magnetic
ballast. Connect incoming ground and lamp
ground to bare ground wire provided in UPM
housing.
See wiring diagram.
11. Position transformer above pre installed screws
located in housing. Slide transformer feet under
two screws in UPM housing and tighten the 4
phillips screws.
Wiring Diagram. See label on cover.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250