![background image](http://html1.mh-extra.com/html/b-k-lighting/pm4rm-round-camlock/pm4rm-round-camlock_safety-and-installation-instructions-manual_3111324004.webp)
REVISION DATE
7-29-09
REFERENCE NUMBER
INS-1555
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM4RM TREE STRAP™
Tree Strap™ Installation (low voltage)
5.
Pull branch circuit wiring necessary for
installation (By Others.)
6.
Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower the
faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety
cable. Do not add weight to, or drop faceplate.
Ground
Hot
Neutral
XFMR
FUSE
FUSE
LAMP COM 2
LAMP COM 1
LAMP 2
LAMP 1
LINE V
COM
8.
Pull secondary leads into UPM housing and
connect to one of the two 15 Amp, 12VAC
circuits on the transformers terminal block.
NOTE: Each circuit is rated for 150 watts
10. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by
tightening the (6) #10-24 captive screws
evenly to 30 in/lbs using a 1/8” allen wrench.
7.
Use a terminal spade (By Others) to connect
branch circuit wires to terminal block on
magnetic transformer. Connect incoming ground
and lamp ground to bare ground wire provided
in UPM housing.
See wiring diagram.
Wiring Diagram. See label on cover.
9.
Position transformer above pre installed screws
located in housing. Slide transformer feet under
two screws in UPM housing and tighten the 4
phillips screws.
4.
Connect 3/4” or 1/2” conduit connector through
female threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit pipe with a suitable
sealant (Teflon tape, adhesive, etc). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250