![background image](http://html1.mh-extra.com/html/b-k-lighting/pm4rm-round-camlock/pm4rm-round-camlock_safety-and-installation-instructions-manual_3111324002.webp)
8.
Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
REVISION DATE
7-29-09
REFERENCE NUMBER
INS-1556
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM4RM ROUND CAMLOCK™
Recessed junction box installation (low voltage)
Ground
Hot
Neutral
A
B
C
10. Pull secondary leads into UPM housing and
connect to one of the two 15 Amp, 12VAC
circuits on the transformers terminal block.
NOTE: Each circuit is rated for 150 watts
12. Make sure UPM housing gasket is free of any dirt
or debris. Attach the faceplate by tightening the
(6) #10-24 captive screws evenly to 30 in/lbs
using a 1/8” allen wrench.
5.
Feed branch circuit wiring into UPM housing.
Install housing on CamLock™ at 90° to finished
orientation as shown. (Figure A)
6.
Rotate housing 90° counter-clockwise (Figure B).
Tighten set screw with 5/64” allen wrench on
outside of UPM housing to lock in place.
(Figure C)
7.
If UPM housing is not level, remove UPM
housing; loosen but
DO NOT REMOVE
(2) #8-32
screws with 9/64” allen wrench on CamLock™
assembly. Adjust CamLock™ assembly up to 30°
as needed to level. Tighten the screws and
reattach UPM housing.
9.
Use wire connectors (By Others) to connect
branch circuit wires to primary leads on magnetic
ballast. Connect incoming ground and lamp
ground to bare ground wire provided in UPM
housing.
See wiring diagram.
XFMR
FUSE
FUSE
LAMP COM 2
LAMP COM 1
LAMP 2
LAMP 1
LINE V
COM
11. Position transformer above pre installed screws
located in housing. Slide transformer feet under
two screws in UPM housing and tighten the 4
phillips screws.
Wiring Diagram. See label on cover.
4.
Feed branch circuit wiring and lamp leads to
remote mounted fixture through mounting plate
with CamLock™ assembly. Attach mounting plate
with supplied (2) #10-24 stainless steel hex drive
fasteners to universal mounting ring using 1/8”
allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250