8.  Remove temporary cover and pull out primary 120V, 

branch circuit wiring.

In-ground installation instructions

Finished grade

Wire nuts must 

clear opening

6” 

min.

9.  Access primary 120V, branch circuit wiring inside 

housing. Make watertight connections using 

waterproof wire connectors (not included). Wire 

connectors must clear opening. Insert fixture, 

wiring and connections into housing. 

See wiring 

diagram.

10.  Mount faceplate to collar using two (2) #8-32 flat 

head screws (included) with a 9/64” allen wrench.

LINE

GROUND

GROUND

FIXTURE

COM

LINE

COM

WIRING DIAGRAM

  Pull branch circuit wiring. Make watertight 

connections from branch circuit wiring to fixture 

leads using waterproof wire connectors (not 

included) in splice location as per NEC. UL Listed 

splice location required. Connect incoming green 

ground wire to ground wire from fixture. 

See wiring 

diagram.

 All line voltage connections must be made in 

compliance with the National Electrical Code. 

Failure to do so will void warranty.

Standard Installation

 DENALI

UPLIGHT - INTEGRAL

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS