8. Remove temporary cover and pull out primary 120V,
branch circuit wiring.
In-ground installation instructions
Finished grade
Wire nuts must
clear opening
6”
min.
9. Access primary 120V, branch circuit wiring inside
housing. Make watertight connections using
waterproof wire connectors (not included). Wire
connectors must clear opening. Insert fixture,
wiring and connections into housing.
See wiring
diagram.
10. Mount faceplate to collar using two (2) #8-32 flat
head screws (included) with a 9/64” allen wrench.
LINE
GROUND
GROUND
FIXTURE
COM
LINE
COM
WIRING DIAGRAM
Pull branch circuit wiring. Make watertight
connections from branch circuit wiring to fixture
leads using waterproof wire connectors (not
included) in splice location as per NEC. UL Listed
splice location required. Connect incoming green
ground wire to ground wire from fixture.
See wiring
diagram.
All line voltage connections must be made in
compliance with the National Electrical Code.
Failure to do so will void warranty.
Standard Installation
DENALI
UPLIGHT - INTEGRAL
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS