background image

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

RELEASE DATE

01/27/2021

REFERENCE NUMBER

INS-2832-00

Installation Instructions

Phase 1 - Rough In

Installation of Back box

1.  Install Conduit (by others) to be used with 

this product. 

2.  Install box so that front face is flush with 

finished wall. Seal building envelope as per 

NEC.

3.  Connect box to conduit and pull wires for 

connections (See wiring diagram).

Additional Info

•  Please follow National and Local electrical codes for your area. 
•  Suitable for through wire
•  Suitable for installation into combustible materials.
•  Rated for 90° C.
•  Junction box, universal mounting ring screws, box mounting hardware 

and gaskets (By Others)

Phase 2 - Finish Installation of Fixture

1.  Pull fixture leads through heavy duty mounting 

plate. Make watertight connections from remote 

driver to fixture leads using waterproof wire 

connectors. (By Others) 

See wiring diagram.

3.  Install mounting plate (supplied with fixture) 

with #10-24 screws using a 1/8” allen wrench 

onto back box. Circled locations are available 

mounting holes for back box installation. 

 

For fixtures with stem length greater than 36”, fixture will not support itself. Structural support cable 

must 

be installed in the field. Please read page 3 for support canopy and safety cable installation.

DENALI SERIES

INTEGRAL DRIVER - TWIN SIGN STAR

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION 

INSTRUCTIONS

2.  Pull branch circuit wiring. Make watertight 

connections from branch circuit wiring 

to fixture leads using waterproof wire 

connectors (by others) in splice location 

as per NEC. UL Listed splice location 

required. Connect incoming green ground 

wire to ground wire from fixture. 

See wiring 

diagram.

WIRING DIAGRAM

 All line voltage connections must be made 

in compliance with the National Electrical 

Code. Failure to do so will void warranty.

LINE

GROUND

GROUND

FIXTURE

COM

LINE

COM

LINE

GROUND

GROUND

FIXTURE

COM

LINE

COM

Summary of Contents for DENALI ST-DE-TR-A

Page 1: ... instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition The use of damaged c...

Page 2: ...waterproof wire connectors By Others See wiring diagram 3 Install mounting plate supplied with fixture with 10 24 screws using a 1 8 allen wrench onto back box Circled locations are available mounting holes for back box installation For fixtures with stem length greater than 36 fixture will not support itself Structural support cable must be installed in the field Please read page 3 for support ca...

Page 3: ...equired 8 Tighten set screw when cable notch in stem is in line with support cable and support canopy 7 Adjust stem so that cable notch in stem lines up with support canopy location and cable Loosen 3 8 set screw in stem to adjust 6 Mount support canopy above fixture location using appropriate mounting hardware for surface by others Seal building envelope as per NEC Do not overtighten Depending on...

Page 4: ...Y AND INSTALLATION INSTRUCTIONS Fixture will not support itself Structural support cable must be installed in the field 7 Use a 3 16 allen wrench to loosen 1 1 4 28 x 1 1 4 stainless steel black oxide socket head cap screw at the knuckle for vertical aiming purpose Tighten 1 1 4 28 x 1 1 4 stainless steel black oxide socket head cap screw to 24 minimum to 48 maximum pounds to secure vertical aimin...

Page 5: ...ate heatsink from driver assembly via quick disconnect 11 Install cap by tightening three 3 8 32 set screws with a 5 64 allen wrench Do not over tighten 10 Twist to reinstall optic onto optic holder 6 Remove protective plastic from the double sided tape square on clean top of driver assembly 7 Reconnect heatsink assembly to driver assembly via quick disconnect Quick disconnect tucks into space und...