40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
RELEASE DATE
01/27/2021
REFERENCE NUMBER
INS-2832-00
Installation Instructions
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (by others) to be used with
this product.
2. Install box so that front face is flush with
finished wall. Seal building envelope as per
NEC.
3. Connect box to conduit and pull wires for
connections (See wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• Suitable for through wire
• Suitable for installation into combustible materials.
• Rated for 90° C.
• Junction box, universal mounting ring screws, box mounting hardware
and gaskets (By Others)
Phase 2 - Finish Installation of Fixture
1. Pull fixture leads through heavy duty mounting
plate. Make watertight connections from remote
driver to fixture leads using waterproof wire
connectors. (By Others)
See wiring diagram.
3. Install mounting plate (supplied with fixture)
with #10-24 screws using a 1/8” allen wrench
onto back box. Circled locations are available
mounting holes for back box installation.
For fixtures with stem length greater than 36”, fixture will not support itself. Structural support cable
must
be installed in the field. Please read page 3 for support canopy and safety cable installation.
DENALI SERIES
INTEGRAL DRIVER - TWIN SIGN STAR
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
INSTRUCTIONS
2. Pull branch circuit wiring. Make watertight
connections from branch circuit wiring
to fixture leads using waterproof wire
connectors (by others) in splice location
as per NEC. UL Listed splice location
required. Connect incoming green ground
wire to ground wire from fixture.
See wiring
diagram.
WIRING DIAGRAM
All line voltage connections must be made
in compliance with the National Electrical
Code. Failure to do so will void warranty.
LINE
GROUND
GROUND
FIXTURE
COM
LINE
COM
LINE
GROUND
GROUND
FIXTURE
COM
LINE
COM