background image

ADJUSTABLE  WELL STAR™  

Installation Instructions

TECHNOLOGY

with

TECHNOLOGY

& Low Voltage 

RELEASE DATE

9-8-15

REFERENCE

 

NUMBER

INS000967

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Replamping for Low Voltage Halogen

2.  Slide fixture body out of aiming bracket.

3.   Use 9/64” Allen wrench to loosen #8-32 stainless 

set screws and remove cap. 

1.   Remove faceplate from housing by loosening 

three (3) #10-24 set screws in faceplate using a 

1/8” Allen wrench.

6.  Slide fixture body into aiming bracket.

7.  Adjust aiming bracket by loosening two (2) 

Phillips screws at sides of bracket. Adjust angle 

as per lighting plan, then secure position by 

tightening two (2) Phillips screws.

8.   Faceplate allows full rotational positioning. 

Loosen three (3) #10-24 set screws in faceplate. 

Align faceplate opening to object to be 

illuminated. Secure faceplate to housing by 

tightening three (3) #10-24 set screws using a 

1/8” Allen wrench.

4.  Firmly insert lamp pins into socket to make 

connection. Rocking motion may be required.

 

Do not exceed the maximum wattage listed on 

the fixture label before installing. 

5.   Use 9/64” Allen wrench to tighten #8-32 

stainless set screws and secure cap. 

 

Warning:  Do not over tighten set screw.  

Doing so will compromise O Ring seal and 

will void warranty.