3. LED Indication 

 
 

Nr.  Indication 

white 

green 

red 

Self-test cycle 
(factory setting) 

Blinking 

Blinking 

Blinking 

Self-test cycle 
(not programmed) 

Blinking 

Self-test cycle 
(programmed via IR) 

Fast 
blinking 

Self-test cycle 
(not prog 
double locked) 

Blinking 

Self-test cycle 
(programmed via IR + 
double locked) 

Fast 
blinking 

Too bright 

Blinking 

IR signal OK 

Short 
ON 

DALI configuration 
mode / grouping 
process 

ON 

ON 

ON 

DALI autoaddressing 

Fast 
blinking 

Fast 
blinking 

Fast 
blinking 

10  Broadcast mode 

ON 

11  Unlocked (parameters 

+ commands) 

ON 

12  Movement detected 

Short 
ON 

 
 

4. Bidirectional Smartphone App 

 
4.1 Preparing smartphone (Android Samsung, iOS) 

 
Please  install  the  app 

B.E.G.  BiRC

, available  in the  respective 

App Store. Depending on the end device it can be necessary to 
update the operating system. For current system requirements 
see application description. 

 
4.2. Preparing IR-Adapter 

 
The IR-Adapter has an integrated rechargeable battery for power 
supply. Please charge the adapter first by means of the micro USB 
cable (included in delivery). The battery being charged. The red 
LED switches off when battery is full. 
 
 

4.3. Connect Adapter with smartphone 

 
Plug the adapter in to the audio socket of your Smartphone or 
tablet. You must ensure that the IR-Adapter is fully inserted into 
the socket. 
Please  note  that  covers  or  cases  may  partially  block  a  correct 
insertion of the adapter into the audio socket. 
Set  the  volume  of  the  audio  socket  to  maximum  in  order  to 
ensure a sufficient transmission range of the IR signal. 
 

5. Smartphone App Parameters 

 
5.1. General 

 

 

LEFT BUTTON 

Select function of the right button 

 

READ OUT 

Read out bidirectional product 
 

 

SEND 

Send selected parameters to the device 
 

 

SEND ALL 

Send all parameters to the device 
(PLEASE  NOTE:  all  set  parameters  will  be 
overwritten,  e.g.  also  the  brightness 
threshold) 
 

 
5.2. Device 

 

 

Software Version 

 

 

Device PIN 

 

 

Lock device 

 

 

DALI Address 

 

 

Sensitivity 

A high (detection) sensitivity being selected, 
even  smaller  movements  will  be  detected 
and larger surfaces will be monitored. 
 

 

Reflection factor

 

 

Summary of Contents for PD4-M-HCL-FC

Page 1: ...gs 4 2 3 Potentiometer and DIP switches 4 2 4 Factory Reset 4 3 LED Indication 5 4 Bidirectional Smartphone App 5 4 1 Preparing smartphone Android Samsung iOS 5 4 2 Preparing IR Adapter 5 4 3 Connect...

Page 2: ...rom warm to cold white This function is used for test or presentation purposes 1 2 2 Application profiles All profiles are designed to activate from morning to afternoon with increasing brightness and...

Page 3: ...rovide teacher or blackboard illumination without a DALI electronic ballast The automatic mode depends on the settings for lighting zone B Group 4 CdS cadmium sulfide relay works as photo electric swi...

Page 4: ...minimised HVAC 5 10 15 light independent HVAC occupancy control HVAC 30 40 50 60 120 light independent HVAC occupancy control with 5 min switch on delay OFF No relay control Moon Night mode 10 lux Se...

Page 5: ...ng IR Adapter The IR Adapter has an integrated rechargeable battery for power supply Please charge the adapter first by means of the micro USB cable included in delivery The battery being charged The...

Page 6: ...approx 3500 and 5500 Kelvin The School profile offers motivating light that supports learning During the day the brightness ranges between approx 350 and 500 lux and the colour temperature between ap...

Page 7: ...as Licht bewegungsunabh ngig bei Unterschreiten der eingestellten Einschaltschwelle ein Abh ngig von der eingestellten Einschaltschwelle ist eine Ein Ausschaltverz gerung aktiv Zone C The interface be...

Page 8: ...self test cycle remain valid Test mode The test mode is for determining the detection area Upon each detected movement the light is switched on HCL test mode The test mode is used to check the colour...

Page 9: ...ortant note for slave operation connect slave devices only after setting up addressing or else ensure that while auto addressing takes place all LEDs blinking quickly no one remains in any slave devic...

Page 10: ...the wall 9 2 Default settings To adjust a desired target value more easily it is recommended to pre set a value using the app and the parameter LUX or via potentiometer which serves as basis for adju...

Reviews: