background image

How often should I clean the system? The answer to this question varies greatly, based on the 

 

cleanliness of your operating conditions. In fairly clean conditions, it is recommended that you clean 

 

the system at least once a week. During emergency conditions the following is recommended:

Maintenance During Normal Use:

(IMPORTANT: To avoid contamination of the system wash hands and use clean materials whenever 

 

having contact with interior surfaces).

Daily:

Discard any unused water stored in the lower bucket for 72 hours or more.

Twice each week:

a. 

Using filtered water, rinse any dirt from inside the Source Water Container.

b. 

Rinse the Pre-Filter Net and Pleated Fibrous Filter and Filter Sleeve (if used) with clear water to remove  

  any debris which may have accumulated.

c. 

Use a cloth dampened with chlorine solution to wipe out the inside of all three containers and the  

 

  spigot. This treatment of the Purification Container and the Spigot is particularly important. Use 1/2    
  teaspoon of household bleach (5.5-6% Chlorine Hypochlorite) per 5 gallons of water.

d. 

Reassemble the system for operation.

e. 

Wipe dirt or debris from the outside of the surface and rinse with clear, clean water.

NOTE:

 

With the exception of the pleated filter and multi-media cartridges, all other surfaces can be ex-

posed to hot soapy water.

General:

 

Track usage to ensure that filters are replaced at the required frequencies stated in the System 

Manual. Remember, the capacity depends upon source water.

2. 

To remove the Multi-Media Filtration 

Cartridge unscrew it from the Filter 
Connector. Remove the 
Gasket from the lower end 
of the Filter Connector.

3. 

To remove the Pleated 

Fibrous Filter from the 
Source Water Container 
unscrew it from the Filter 
Connector while gripping 
the lower end of the Filter 
Connector. Remove the 
Gasket from the upper end of the Filter 
Connector and remove the Filter Connector.

1. 

Remove Pre-Filter Net 

and lift the entire assembly 
off of the Purified Water 
Container by the lid. The 
Source Water Container 
and cartridge assembly 
are all attached to the lid.

D I S A S S E M B LY   F O R   M A I N T E N A N C E ,   F I LT E R   R E P L A C E M E N T   O R   S T O R A G E

WP-1924

   

Pour-Through Water Purification and Filtration System 

 5

For cleaning and maintenance, filter replacement, transportation or for ease of storage your system must 
sometimes be disassembled. To do so, follow the directions found below. Be sure to wash your hands 
thoroughly with soap and water before handling system components. (For more detail see assembly 
instructions on pages 4 and 5.)

It is very important that your system be kept clean at all times. When cleaning the spigot, as well as the inside and 
outside of the pails, make sure to use a clean cloth dampened with chlorine. Used or dirty towels will expose the sys-
tem to contaminants which can cause illness.

M A I N T E N A N C E   A N D   C L E A N I N G

Summary of Contents for WP-1924

Page 1: ...TION MANUAL Patent Pending FOR SYSTEMS FILTERS SERVICE t 952 884 8417 e info bdavidwater com w bdavidwater com B David Company World Health Through Water Purification Systems WP 1924 Pour Through Water Purification and Filtration System ...

Page 2: ...ess First a coarse cloth filter stretched over the top of the source water pail removes large sediment particles turbidity dirt and debris Then a filtration sleeve surrounding the purification cartridge removes any additional sedimentation and turbidity Next the nano filtration stage eliminates bacteria cysts and virus Finally the Multi media Cartridge absorbs chemicals organic matter environmenta...

Page 3: ... Fibrous Filter WP 2050 optional 5 Pleated Fibrous Nano Filter WP 1803 6 Gasket for top end of filter connector 7 Filter Connector FC 8 Gasket for Multi Media Cartridge 9 Purified Water Container Lid 10 Purified Water Container 5 gal 11 Multi Media Cartridge WP 1802 12 Spigot Assembly 13 Assembly and Operation Manual WP 1924 Pour Through Water Purification and Filtration System 2 Source Water Lid ...

Page 4: ...d with the threaded end of the Filter Connector projecting through the hole in the bottom of the container 4 Place the smallest of the white Gaskets over the threaded end of the Filter Connecter 5 Thread the Pleated Fibrous Filter Cartridge onto the threaded end of the Filter Connector in the Source Water Container Hand tighten until the end of the filter seats firmly against the Gasket and the Ga...

Page 5: ...cteria and virus then down through the center of the Filter Con nector The water then enters the Multi Media Cartridge where chemi cals pesticides herbi cides organic matter and other contaminants are absorbed by the Multi Media Cartridge removing toxins bad tastes and odors from the water The water is ready to drink as soon as it enters the Purified Water Con tainer There is no need to wait for t...

Page 6: ...ure that filters are replaced at the required frequencies stated in the System Manual Remember the capacity depends upon source water 2 To remove the Multi Media Filtration Cartridge unscrew it from the Filter Connector Remove the Gasket from the lower end of the Filter Connector 3 To remove the Pleated Fibrous Filter from the Source Water Container unscrew it from the Filter Connector while gripp...

Page 7: ... to place all cleaned components and filters on a clean surface to avoid contamination 4 Remove Spigot and associated washers and nuts 5 Replace the sanitary caps in the holes left by the Filter Connector and the Spigot 6 Place the Spigot and Spigot parts Gaskets and Filter Connecter in a re sealable plastic parts bag 7 Place the Pre Filter Net Filtration Sleeve Multi Media Cartridge the Pleated F...

Page 8: ...red When should I replace the Multi Media Filter Cartridge Item WP 1802 After approximately 6 500 liters 1 800 gal lons or 12 months of use you will need to replace the Multi Media Filtration Cartridge If you notice any changes in taste and or odor this is also a good indication that the Multi Media Cartridge is in need of replace ment To replace the cartridge please follow the detailed steps foun...

Page 9: ...ENSIONS American Standard Assembled 24 x 11 75 Boxed 18 x 12 x 12 WEIGHT Boxed 8 00 lbs Empty 6 75 lbs When filled with water 45 50 lbs CUBE 1 5 ft3 FLOW RATE 6 12 Gallons Day depending on water conditions CAPACITY 1 800 Gallons or diminished flow OPERATING TEMPERATURE 42 F to 125 F CARTRIDGES 7 Pleated Fibrous Purification Filter WP 1803 10 Multi Media Filtration Cartridge WP 1802 APPLICATIONS Fr...

Page 10: ...The pleated filter or multi media cartridge may be plugged First check the Pleated Filter using the following steps 1 Remove the source water pail and the double lid with the filters attached from the system 2 Remove the pleated filter from the filter connector 5 Clean and rinse the pleated filter following the steps located on page 8 of this manual 3 After cleaning the pleated filter reinstall it...

Page 11: ...y period set forth above All returns to The B David Company require a Return Authorization Number This Limited Warranty will not apply to any product which has been altered incorrectly installed misused abused or used for any other application other than personal household use The B David Company specifically disclaims any warranty of any kind on such products THE LIMITED WARRANTY SET FORTH ABOVE ...

Page 12: ...T E N A N C E Date Activity Service Performed Installation Date B David Company World Health Through Water Purification Systems Tel 952 884 8417 Email info bdavidwater com Visit our website www bdavidwater com ...

Reviews: