IE
-MultiWay
33
BRANCH/LEAF
A port may be configured as a Branch, and two other ports as a Leaf. The Leaf ports
cannot talk to each other, providing another layer of security, but each Leaf can talk to the
Branch.
USING IVIEW
2
iView² is B+B SmartWorx’ management software, providing network management in an
easy to use GUI. Once iView² is installed on a network management PC using a Windows
operating system, use the Start menu to access iView². iView² is available in a desktop or
webserver version.
NOTE
:
Windows SNMP services must be installed to receive traps.
The autoscan feature of iView² will detect B+B SmartWorx’ devices on an active subnet
and list them in the network outline. Click the connection for the IE-MultiWay to open its
iView² screen. To perform additional configuration, select the iView
2
iConfig view icon on
the toolbar in iView². This allows a session to be launched, and the default
password/username is admin/admin. Additional private usernames and passwords can be
entered in the USERS tab. If the list of passwords is not maintained, the usernames and
passwords can be reset by opening a CLI session and typing in the
cleandb
command.
This will reset all but the IP address of the device.