PROSCRUB OWNER’S MANUAL PAGE
15
08-2017
BATTERY CHARGING continued
Safety first. Contact an authorized service center as needed.
To get the most life from your battery, recharge when the meter drops into the
red zone. Do not continue to run the scrubber after meter has gone into the red zone.
Do not let batteries sit uncharged for long periods of time.
Do not operate this scrubber if it is not in proper operating condition.
GEL BATTERIES: Gel batteries are maintenance free and levels do not need to be checked.
LEAD ACID BATTERIES: Lead acid batteries must have fluid checked every 10 charges. If fluid is low,
fill with distilled water to top of plates.
Battery charger specifications:
Output voltage
– 24 volts
Output current
– 10 to 20 amps
Automatic shutoff circuit
For deep cycle battery charging, life expectancy of a battery is based on the number of charges it
receives. To get the most life from your battery, recharge when the meter drops into the red zone.
1)
Make sure all switches are in the “OFF” position.
2) Open recovery tank to access batteries.
3) Plug charger into receptacle near battery compartment.
4) Plug charger into grounded wall outlet AFTER connecting charger to scrubber. Charger will
automatically begin charging and will shut off automatically when batteries are fully charged.
5) Do not use an adapter or remove grounded blade on plug.
6) After charger has turned off, first unplug it from the wall outlet, then from the scrubber.