Technical Principles
1ª review – UK 12 – 2020
18
3.
INSTALLATION AND SWITCHING ON
3.1. Installation
The power supply of the machine requires a socket, or another system, that allows its disconnection.
The method used must guarantee the complete disconnection of both poles.
Elemental safety requirements:
a) Never touch any mechanisms with wet hands or feet.
b) Never connect or use the machine barefoot.
c) Never pull on the flex to unplug the machine.
d) Never leave the machine exposed to the elements: sun, rain, snow, etc.
3.2 Water connection
The machine can operate connected to the hydraulic grid or with a battery unit. For connection to
the hydraulic mains has a
3/4-inch male socket
. It shall be connected to a drinking water intake
supplying a minimum flow rate of 5 liters/minute at a pressure between 0.5 and 10 kg/cm2.
The hydraulic mains connection hose is not supplied with the machine.
According to the low voltage regulation, the distance between the water intake and any electrical
plug base will have a minimum of
1 meter.
L1. Línea de agua
L2. Distancia minima 1 metro
Depending on water quality, degree of
hardness; chlorine; bleach; etc., the
installation should be complemented by a
resin scrubber filter
.
If the machine incorporates a scrubber filter or softener filter, the minimum network pressure must
be
1 Kg/cm2.