Technical Principles
1ª review – UK 12 – 2020
14
The water recedes back from the infusion element towards the third outlet because of the
pressure it was submitted to by the pump in the infusion process.
I1. 3rd outlet open
I2. Infusion element joined to atmospheric pressure
I3. Boiler water closed
Technical Characteristics:
Heating element voltage
230 Vca
Power
1.100 w
Temperature programming
70ºC -94ºC
Safety protection with manual reset
120º C
Voltage of 3-way EV
24 Vcc
Power of 3-way EV
10 w
Maximum pressure of EV
14 Kg./cm²
Working temperature of EV
-10º C a 140º C
Temperature control of the water in the boiler is done with a PTC100. Default Temperature
from factory is programmed to 85ºC, it can be programmed up to 96ºC.
It must be taken into account that, depending on the altitude at which the
machine is installed, the water can boil at a temperature below 100ºC.
Altitud (meters)
(above sea level)
Boiling water
temperature
Max. advised temp. in
boiler (F461)
1500
95ºC
92ºC
1800
94ºC
91ºC
2100
93ºC
90ºC
2400
92ºC
89ºC
2700
91ºC
88ºC
The following table shows the resistance values that the PT100 gives according to the
temperature that it is submitted.