42
07 - 2009
6.4 ADJUSTING THE MAXIMUM AND MINIMUM LEVELS IN THE HOPPER
To fit the optic sensors in the positions desired, we recommend following these instructions:
1
Select the location for the minimum and maximum sensor with respect to your
needs. For information on capacity, see the data shown in point
3.4.3 Coin level
detection.
2
Pull gently on each optic sensor to remove them from their present position.
3
Insert the pairs of optic sensors in the empty and full positions, making sure they
are horizontally level. Press lightly the sensors to fit them in their holes.
4
The excess cable must be stored using the plastic clips found on the hopper or by
introducing the loop of extra cable into the cavities found in the hopper on its
underside.
For this operation you need:
•
A flat screwdriver with a 3 to 5 mm point
•
The mechanical parts necessary for the
configuration chosen:
−
Track
−
Coin concentrator
−
Flap.
Summary of Contents for t3 hopper
Page 40: ...40 07 2009 6 7 8 9...