Automatic saving of last programme used.
When the machine is turned on again, the parameters from the last programme selected and
started will be loaded
Saving programs in ROM.
To save, press and hold for at least 3 seconds the button "E". Saving is possible in the
absence of lock,defined function F00. If saving was successful, the left point will begin to flash
rapidly for a second.If F00 not allow you to save, it is necessary to change the value of this
function from 1 to 0.
Cancel the current program.
To cancel, press and hold the button STOP for at least 5 seconds. During this time running
program will have time to switch to pause (the turntable and the carriage stop), and then there
will be cancellation of the program.
Alarms
The V display is used for showing the alarms, noted at
the same time by the flashing LED
next to the key RESET
:
E 0
: no cargo on the turntable
E 1
: forklift on the turntable
(
transpallet turntable)
E 2
: turntable drive error
E 4
:
obstacle under carriage
E16
:
carriage door alarm
E99
:
control panel error
... :
control panel does not initializ
ed
Signals LED 3
- FLASHING: EEPROM fault
- ON: keyboard blocked (V+ and V- blocked)
- OFF: keyboard released.
Keyboard block
:
prevents modification of parameters by blocking thr key V+ and V-; hold down RESET and
at the same time press F+ and F-. The LED of the display V lights up and stays lit.