5.2.2 CONTROL PANEL FUNCTIONS
F00 This parameter is used to prevent cycle parameters from being overwritten.
0 - disabled, 1 - enabled
F01
01
02
03
and 5.2.4)
F02
Table rotation speed: selectable from 0 to 100
F03
Carriage up speed: selectable from 0 to 100
F04
Carriage down speed: selectable from 0 to 100
F05
Number of bottom wraps
F06
Number of top wraps
F07
Number of middle wraps (F08
≠
0)
F08
The distance from the floor to the bottom edge of the film - height at which the F07
wraps produced
F09
Strip of film placed over the top of the product
F10
The height of the carriage at which turntable starts
F11
The height of the carriage at which turntable stops
F12
Height at which the carriage stops rising, referred to the upper edge of the roll of film
(product presence photocell disabled)
F22
Cycle with pause: enabled 1 or disabled 0
F23
Carriage descent position with F22 = 1
F
50
Film width
: 40 - 60 см
Set cycle:
up and down
up or down,
manual cycle (see sections 5.2.3.
34