22
■
Tables for accuracy after temperature and pressure compensation (in air)
Unit of flow rate: m
3
/h (actual @ 23°C)
Accuracy differs according to operating pressure and flow rate range.
●
MVF050 (Pipe size 50A)
●
MVF080 (Pipe size 80A)
Chapter 5. SPECIFICATIONS
Operating
Minimum mea-
pressure
surable flow rate
Accuracy
(MPa)
Q min
0.10
7.4
±Qmin
±6.7% RD
±5.7% RD
7.4
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
428
0.15
7.4
±Qmin
±6.0% RD
±4.9% RD
7.4
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
535
0.20
7.4
±Qmin
±5.6% RD
±4.4% RD
7.4
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
641
0.30
8.5
±Qmin
±5.1% RD
±3.8% RD
8.5
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
854
0.40
10.7
±Qmin
±4.9% RD
±3.5% RD
10.7
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
1067
0.50
12.8
±Qmin
±4.8% RD
±3.3% RD
12.8
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
1280
0.60
14.9
±Qmin
±4.7% RD
±3.2% RD
14.9
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
1493
0.70
17.1
±Qmin
±4.6% RD
±3.1% RD
17.1
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
1706
0.80
19.2
±Qmin
±4.6% RD
±3.0% RD
19.2
≤
Q
≤
32
32 < Q < 74
74
≤
Q
≤
1919
0.90
21.3
±Qmin
±4.6% RD
±3.0% RD
21.3
≤
Q
≤
36
36 < Q < 74
74
≤
Q
≤
2131
0.98
23.0
±Qmin
±4.6% RD
±3.0% RD
23.0
≤
Q
≤
38
38 < Q < 74
74
≤
Q
≤
2302
Operating
Minimum mea-
pressure
surable flow rate
Accuracy
(MPa)
Q min
0.10
11.0
±Qmin
±6.7% RD
±5.7% RD
11.0
≤
Q
≤
31
31 < Q < 110
110
≤
Q
≤
946
0.15
11.8
±Qmin
±6.0% RD
±4.9% RD
11.8
≤
Q
≤
31
31 < Q < 110
110
≤
Q
≤
1181
0.20
14.2
±Qmin
±5.6% RD
±4.4% RD
14.2
≤
Q
≤
31
31 < Q < 110
110
≤
Q
≤
1416
0.30
18.9
±Qmin
±5.1% RD
±3.8% RD
18.9
≤
Q
≤
31
31 < Q < 110
110
≤
Q
≤
1886
0.40
23.6
±Qmin
±4.9% RD
±3.5% RD
23.6
≤
Q
≤
39
39 < Q < 110
110
≤
Q
≤
2355
0.50
28.3
±Qmin
±4.8% RD
±3.3% RD
28.3
≤
Q
≤
47
47 < Q < 110
110
≤
Q
≤
2825
0.60
33.0
±Qmin
±4.7% RD
±3.2% RD
33.0
≤
Q
≤
55
55 < Q < 110
110
≤
Q
≤
3295
0.70
37.6
±Qmin
±4.6% RD
±3.1% RD
37.6
≤
Q
≤
63
63 < Q < 110
110
≤
Q
≤
3765
0.80
42.3
±Qmin
±4.6% RD
±3.0% RD
42.3
≤
Q
≤
71
71 < Q < 110
110
≤
Q
≤
4235
0.90
47.0
±Qmin
±4.6% RD
±3.0% RD
47.0
≤
Q
≤
78
78 < Q < 110
110
≤
Q
≤
4705
0.98
50.8
±Qmin
±4.6% RD
±3.0% RD
50.8
≤
Q
≤
85
85 < Q < 110
110
≤
Q
≤
5081