Chapter 4. OPERATION
When the integrated flow rate is
10000
m
3
or more, pressing the
key displays the first four digits of the integrated flow rate.
You can also alternately display the first four digits and the last four
digits by repeatedly pressing the
key.
For example, if initial reading is
1234
and the 2nd reading is _ _
56
,
the integrated flow rate is _ _
561234
m
3
.
If the
key is held down for at least five seconds when switching
to the integrated flow rate display from the instantaneous flow rate
display, digits past the decimal point for the integrated flow rate are
displayed.
Handling Precautions
•
When the flow rate exceeds the upper limit of the measurement
range, the OVER indicator light, and goes out after the flow rate
returns to within the measurement range.
•
The integrated flow rate factory setting is
0
.
•
The integrated flow rate indication returns to
0
after
99999999
is
exceeded.
•
The flow rate is integrated even if the flow rate is outside of the
measurement range. Regard integrated values as a means for
grasping the whole quantity of flow.